Preparation of molecularly imprinted polymers for sensing of 2,4-dichlorophenoxyacetic acid residues in environmental water and mixed juice
Journal of Materials Science ( IF 3.5 ) Pub Date : 2020-03-04 , DOI: 10.1007/s10853-020-04516-7
Xuewen Wu , Tiantian Jiao , Changli Xu , Wei Li , Yan Xiong

In this paper, we reported a rapid and simple approach to synthesize molecularly imprinted polymers (MIPs) materials for sensing of 2,4-dichlorophenoxyacetic acid (2,4-D) residues in environmental water and mixed juice. Initially, MIPs materials were prepared via visible light-initiated reversible addition-fragmentation chain transfer (RAFT) emulsion polymerization at ambient temperature using 2,4-D and its analogs as template molecules, in which 4-vinyl pyridine (4-VP), ethylene glycol dimethacrylate (EGDMA), (2,4,6-trimethylbenzoyl) diphenylphosphine oxide (TPO), 2-(((dodecylthio)carbonothioyl)thio)-2-methylpropanoic acid (DDMAT) were functional monomer, cross-linker, visible light initiator and RAFT agent, respectively. Then, the morphologies of the MIPs materials were characterized by FT-IR, SEM and DLS. The results showed that the MIPs materials were well-distributed spherical particles with sizes ranging from 1 to 2 μm. Furthermore, a four-channel MIPs sensor array included four polymer microspheres with a fluorescent dye displacement procedure was developed to distinguish the templates and their chemical analogs at the ppm concentration level. With the support of principal component analysis and hierarchical cluster analysis, the four-channel MIPs sensor array proves to be a simple and effective method to recognize and distinguish the templates and nontemplates in aqueous solution with 100% accuracy. Finally, the four-channel MIPs sensor array was also found to have satisfactory accuracy in monitoring 2,4-D contaminated environmental water and mixed juice.

中文翻译:

用于检测环境水和混合果汁中 2,4-二氯苯氧乙酸残留的分子印迹聚合物的制备

在本文中,我们报道了一种快速简单的合成分子印迹聚合物 (MIP) 材料的方法,用于检测环境水和混合果汁中的 2,4-二氯苯氧乙酸 (2,4-D) 残留物。最初,MIPs 材料是通过可见光引发的可逆加成断裂链转移 (RAFT) 乳液聚合在室温下使用 2,4-D 及其类似物作为模板分子制备的,其中 4-乙烯基吡啶 (4-VP)、乙二醇二甲基丙烯酸酯(EGDMA)、(2,4,6-三甲基苯甲酰基)二苯基氧化膦(TPO)、2-((((十二烷基硫基)碳硫酰基)硫代)-2-甲基丙酸(DDMAT)为功能单体、交联剂、可见光分别是光引发剂和 RAFT 剂。然后,MIPs 材料的形貌通过 FT-IR、SEM 和 DLS 进行表征。结果表明,MIPs 材料为分布均匀的球形颗粒,粒径范围为 1 至 2 μm。此外,开发了一个四通道 MIP 传感器阵列,包括四个聚合物微球,采用荧光染料置换程序,以在 ppm 浓度水平区分模板及其化学类似物。在主成分分析和层次聚类分析的支持下,四通道MIPs传感器阵列被证明是一种简单有效的方法,可以100%准确地识别和区分水溶液中的模板和非模板。最后,还发现四通道 MIP 传感器阵列在监测 2,4-D 污染环境水和混合果汁方面具有令人满意的准确性。此外,开发了一个四通道 MIP 传感器阵列,包括四个聚合物微球,采用荧光染料置换程序,以在 ppm 浓度水平区分模板及其化学类似物。在主成分分析和层次聚类分析的支持下,四通道MIPs传感器阵列被证明是一种简单有效的方法,可以100%准确地识别和区分水溶液中的模板和非模板。最后,还发现四通道 MIP 传感器阵列在监测 2,4-D 污染环境水和混合果汁方面具有令人满意的准确性。此外,开发了一个四通道 MIP 传感器阵列,包括四个聚合物微球,采用荧光染料置换程序,以在 ppm 浓度水平区分模板及其化学类似物。在主成分分析和层次聚类分析的支持下,四通道MIPs传感器阵列被证明是一种简单有效的方法,可以100%准确地识别和区分水溶液中的模板和非模板。最后,还发现四通道 MIP 传感器阵列在监测 2,4-D 污染环境水和混合果汁方面具有令人满意的准确性。四通道 MIPs 传感器阵列包括四个聚合物微球,采用荧光染料置换程序,以在 ppm 浓度水平区分模板及其化学类似物。在主成分分析和层次聚类分析的支持下,四通道MIPs传感器阵列被证明是一种简单有效的方法,可以100%准确地识别和区分水溶液中的模板和非模板。最后,还发现四通道 MIP 传感器阵列在监测 2,4-D 污染环境水和混合果汁方面具有令人满意的准确性。四通道 MIPs 传感器阵列包括四个聚合物微球,采用荧光染料置换程序,以在 ppm 浓度水平区分模板及其化学类似物。在主成分分析和层次聚类分析的支持下,四通道MIPs传感器阵列被证明是一种简单有效的方法,可以100%准确地识别和区分水溶液中的模板和非模板。最后,还发现四通道 MIP 传感器阵列在监测 2,4-D 污染环境水和混合果汁方面具有令人满意的准确性。四通道 MIPs 传感器阵列被证明是一种简单有效的方法来识别和区分水溶液中的模板和非模板,准确度为 100%。最后,还发现四通道 MIP 传感器阵列在监测 2,4-D 污染环境水和混合果汁方面具有令人满意的准确性。四通道 MIPs 传感器阵列被证明是一种简单有效的方法来识别和区分水溶液中的模板和非模板,准确度为 100%。最后,还发现四通道 MIP 传感器阵列在监测 2,4-D 污染环境水和混合果汁方面具有令人满意的准确性。
更新日期:2020-03-04
down
wechat
bug