当前位置:
X-MOL 学术
›
Ann. Intensive Care
›
论文详情
Our official English website, www.x-mol.net, welcomes your
feedback! (Note: you will need to create a separate account there.)
Changes in dynamic arterial elastance induced by volume expansion and vasopressor in the operating room: a prospective bicentre study
Annals of Intensive Care ( IF 5.7 ) Pub Date : 2019-10-11 , DOI: 10.1186/s13613-019-0588-6 Hugues de Courson , Philippe Boyer , Romain Grobost , Romain Lanchon , Musa Sesay , Karine Nouette-Gaulain , Emmanuel Futier , Matthieu Biais
中文翻译:
手术室中容积扩张和血管加压药诱导的动态动脉弹性变化:一项前瞻性bicentre研究
更新日期:2019-10-11
Annals of Intensive Care ( IF 5.7 ) Pub Date : 2019-10-11 , DOI: 10.1186/s13613-019-0588-6 Hugues de Courson , Philippe Boyer , Romain Grobost , Romain Lanchon , Musa Sesay , Karine Nouette-Gaulain , Emmanuel Futier , Matthieu Biais
Background
Dynamic arterial elastance (Eadyn), defined as the ratio between pulse pressure variations and stroke volume variations, has been proposed to assess functional arterial load. We evaluated the evolution of Eadyn during volume expansion and the effects of neosynephrine infusion in hypotensive and preload-responsive patients.Methods
In this prospective bicentre study, we included 56 mechanically ventilated patients in the operating room. Each patient had volume expansion and neosynephrine infusion. Stroke volume and stroke volume variations were obtained using esophageal Doppler, and pulse pressure variations were measured through the arterial line. Pressure response to volume expansion was defined as an increase in mean arterial pressure (MAP) ≥ 10%.Results
Twenty-one patients were pressure responders to volume expansion. Volume expansion induced a decrease in Eadyn (from 0.69 [0.58–0.85] to 0.59 [0.42–0.77]) related to a decrease in pulse pressure variations more pronounced than the decrease in stroke volume variations. Baseline and changes in Eadyn after volume expansion were related to age, history of arterial hypertension, net arterial compliance and effective arterial elastance. Eadyn value before volume expansion > 0.65 predicted a MAP increase ≥ 10% with a sensitivity of 76% (95% CI 53–92%) and a specificity of 60% (95% CI 42–76%). Neosynephrine infusion induced a decrease in Eadyn (from 0.67 [0.48–0.80] to 0.54 [0.37–0.68]) related to a decrease in pulse pressure variations more pronounced than the decrease in stroke volume variations. Baseline and changes in Eadyn after neosynephrine infusion were only related to heart rate.Conclusion
Eadyn is a potential sensitive marker of arterial tone changes following vasopressor infusion.中文翻译:
手术室中容积扩张和血管加压药诱导的动态动脉弹性变化:一项前瞻性bicentre研究