Electrochemically applied hydroxyapatite on the cementless porous surface of Bi-Metric stems reduces early migration and has a lasting effect : an efficacy trial of a randomized five-year follow-up radiostereometric study.
The Bone & Joint Journal ( IF 4.9 ) Pub Date : 2022-6-1 , DOI: 10.1302/0301-620x.104b6.bjj-2021-1545.r1
Martin B Knudsen 1, 2 , Janni K Thillemann 1, 2, 3 , Peter B Jørgensen 1, 2 , Stig S Jakobsen 1, 4 , Henrik Daugaard 5 , Kjeld Søballe 1, 4 , Maiken Stilling 1, 2, 4
Affiliation  

BoneMaster is a thin electrochemically applied hydroxyapatite (HA) coating for orthopaedic implants that is quickly resorbed during osseointegration. Early stabilization is a surrogacy marker of good survival of femoral stems. The hypothesis of this study was that a BoneMaster coating yields a fast early and lasting fixation of stems.

中文翻译:

在 Bi-Metric 茎的非水泥多孔表面上电化学应用羟基磷灰石可减少早期迁移并具有持久效果:一项为期五年的随机随访放射立体测量研究的功效试验。

BoneMaster 是一种用于骨科植入物的薄电化学应用羟基磷灰石 (HA) 涂层,在骨整合过程中可快速吸收。早期稳定是股骨柄良好存活的替代标志。这项研究的假设是,BoneMaster 涂层可以快速、早期和持久地固定茎。