当前位置: X-MOL 学术IEEE Sens. J. › 论文详情
Our official English website, www.x-mol.net, welcomes your feedback! (Note: you will need to create a separate account there.)
A Microfiber-Based Sensor for Simultaneous Measurement of Acetaminophen and Temperature
IEEE Sensors Journal ( IF 4.3 ) Pub Date : 2021-08-24 , DOI: 10.1109/jsen.2021.3097362
Yuting Bai , Yinping Miao , Hongmin Zhang , Chengwei Fei , Bin Li , Kailiang Zhang

A fiber-optic sensor based on a microfiber coupler (MFC) for dual parameter detection of acetaminophen and temperature is proposed. The microfiber structure is manufactured by hydrogen-oxygen flame-heating technology. The characteristics of the transmission spectrum were studied theoretically and experimentally under conditions of different acetaminophen concentrations and temperatures. Acetaminophen concentration detection sensitivities of 102.4 pm/( μmol/mL) and -0.01 dB/( μmol/mL) in the range of 10 - 50 μmol/mL, as well as temperature sensitivities of -0.32 nm/°C and -0.001 dB/°C, were obtained for the proposed sensor. These results indicate that the photonic sensor has potential as a tool for pharmaceutical quality control and hospital wastewater treatment.

中文翻译:


用于同时测量对乙酰氨基酚和温度的微纤维传感器



提出了一种基于微光纤耦合器(MFC)的光纤传感器,用于对乙酰氨基酚和温度的双参数检测。超细纤维结构采用氢氧火焰加热技术制造。从理论上和实验上研究了不同对乙酰氨基酚浓度和温度条件下的透射光谱特征。在 10 - 50 μmol/mL 范围内对乙酰氨基酚浓度检测灵敏度为 102.4 pm/( μmol/mL) 和 -0.01 dB/( μmol/mL),温度灵敏度为 -0.32 nm/°C 和 -0.001 dB /°C,是针对所提出的传感器获得的。这些结果表明光子传感器具有作为药品质量控制和医院废水处理工具的潜力。