当前位置: X-MOL 学术Adv. High Energy Phys. › 论文详情
Our official English website, www.x-mol.net, welcomes your feedback! (Note: you will need to create a separate account there.)
Determination of Position Resolution for LYSO Scintillation Crystals Using Geant4 Monte Carlo Code
Advances in High Energy Physics ( IF 1.5 ) Pub Date : 2021-09-15 , DOI: 10.1155/2021/9931708
M. F. O. Yahya 1 , F. Kocak 1
Affiliation  

LYSO scintillation crystals, due to their significant characteristics such as high light yield, fast decay time, small Moliére radius, and good radiation hardness, are proposed to be used for the electromagnetic calorimeter section of the Turkish Accelerator Center Particle Factory (TAC-PF) detector. In this work, the center of gravity technique was used to determine the impact coordinates of an electron initiating an electromagnetic shower in a LYSO array, in a calorimeter module containing nine crystals, each in cross-section and 200 mm in length. The response of the calorimeter module has been studied with electrons having energies in the range 0.1 GeV-2 GeV. By using the Monte Carlo simulation based on Geant4, the two-dimensional position resolution of the module is obtained as at the center of the crystal.

中文翻译:

使用 Geant4 蒙特卡罗代码确定 LYSO 闪烁晶体的位置分辨率

LYSO闪烁晶体由于具有光产率高、衰减时间快、莫里埃半径小、辐射硬度好等显着特点,拟用于土耳其加速器中心粒子厂(TAC-PF)的电磁量热仪部分探测器。在这项工作中,重心技术用于确定在 LYSO 阵列中引发电磁簇射的电子的撞击坐标,该阵列包含九个晶体的热量计模块,每个晶体横截面和 200 毫米长。已经使用能量在 0.1 GeV-2 GeV 范围内的电子研究了热量计模块的响应。使用基于Geant4的蒙特卡罗模拟,得到模块的二维位置分辨率为 在水晶的中心。
更新日期:2021-09-15
down
wechat