当前位置: X-MOL 学术Ultrasonics › 论文详情
Our official English website, www.x-mol.net, welcomes your feedback! (Note: you will need to create a separate account there.)
Speed of sound in the IEC tissue-mimicking material and its maintenance solution as a function of temperature
Ultrasonics ( IF 3.8 ) Pub Date : 2021-08-27 , DOI: 10.1016/j.ultras.2021.106564
Raquel Monteiro Souza 1 , Mylena Kathleen M de Assis 1 , Rodrigo Pereira Barretto da Costa-Félix 1 , Andre Victor Alvarenga 1
Affiliation  

Tissue-Mimicking Material (TMM) is defined on IEC International Standards and applied in assessing ultrasonic diagnostic and therapeutic equipment's basic safety and essential performance. One of the TMM that fits IEC standards specification has its recipe described at IEC 60601-2-37, and it is fabricated using glycerol (11.21 %), deionized water (82.95%), benzalkonium chloride (0.47 %), silicon carbide (0.53 %), aluminum oxide 0.3 μm (0.88%), aluminum oxide 3.0 μm (0.94 %), and agar (3.08 %). Glycerol is the component responsible for adjusting the TMM's speed of sound. Moreover, it is recommended to store TMM in a closed container immersed in a mixture of water (88.1 %)/glycerol (11.9 %) to prevent it from drying out and avoiding air contact. The literature points out TMM measurements underwater can alter the speed of sound property as TMM tends to lose glycerol. Herein, the authors proposed to assess the viability of measuring the TMM speed of sound in the water/glycerol maintenance solution. First, the authors characterized the maintenance solution's speed of sound for a temperature range of 20 °C to 45 °C. Then, the group velocity of a set of TMM was measured underwater and in the maintenance solution for the same temperature range. The respective group velocity expanded uncertainty was calculated. The results indicate it is feasible to measure TMM in the maintenance solution, achieving group velocity values with no statistical difference from the ones measured underwater in the temperature range of 20 °C to 40 °C.



中文翻译:

IEC 组织模拟材料中的声速及其作为温度函数的维护解决方案

组织模拟材料 (TMM) 在 IEC 国际标准中定义,用于评估超声诊断和治疗设备的基本安全性和基本性能。符合 IEC 标准规范的 TMM 之一的配方在 IEC 60601-2-37 中有描述,它使用甘油 (11.21%)、去离子水 (82.95%)、苯扎氯铵 (0.47%)、碳化硅 (0.53 %)、氧化铝 0.3 μm (0.88%)、氧化铝 3.0 μm (0.94%) 和琼脂 (3.08%)。甘油是负责调整 TMM 声速的成分。此外,建议将 TMM 储存在浸没在水 (88.1%)/甘油 (11.9%) 混合物中的密闭容器中,以防止其变干并避免与空气接触。文献指出水下 TMM 测量可以改变声速特性,因为 TMM 往往会失去甘油。在此,作者提议评估在水/甘油维持溶液中测量 TMM 声速的可行性。首先,作者描述了维护解决方案在 20 °C 至 45 °C 温度范围内的声速。然后,在相同温度范围内,在水下和维护溶液中测量了一组 TMM 的群速度。计算各自的群速度扩展不确定度。结果表明,在维护解决方案中测量 TMM 是可行的,在 20 °C 到 40 °C 的温度范围内,获得的群速度值与水下测量的群速度值没有统计学差异。作者提议评估在水/甘油维持溶液中测量 TMM 声速的可行性。首先,作者描述了维护解决方案在 20 °C 至 45 °C 温度范围内的声速。然后,在相同温度范围内,在水下和维护溶液中测量了一组 TMM 的群速度。计算各自的群速度扩展不确定度。结果表明,在维护解决方案中测量 TMM 是可行的,在 20 °C 到 40 °C 的温度范围内,获得的群速度值与水下测量的群速度值没有统计学差异。作者提议评估在水/甘油维持溶液中测量 TMM 声速的可行性。首先,作者描述了维护解决方案在 20 °C 至 45 °C 温度范围内的声速。然后,在相同温度范围内,在水下和维护溶液中测量了一组 TMM 的群速度。计算各自的群速度扩展不确定度。结果表明,在维护解决方案中测量 TMM 是可行的,在 20 °C 到 40 °C 的温度范围内,获得的群速度值与水下测量的群速度值没有统计学差异。s 在 20 °C 到 45 °C 的温度范围内的声速。然后,在相同温度范围内,在水下和维护溶液中测量了一组 TMM 的群速度。计算各自的群速度扩展不确定度。结果表明,在维护解决方案中测量 TMM 是可行的,在 20 °C 到 40 °C 的温度范围内,获得的群速度值与水下测量的群速度值没有统计学差异。s 在 20 °C 到 45 °C 的温度范围内的声速。然后,在相同温度范围内,在水下和维护溶液中测量了一组 TMM 的群速度。计算各自的群速度扩展不确定度。结果表明,在维护解决方案中测量 TMM 是可行的,在 20 °C 到 40 °C 的温度范围内,获得的群速度值与水下测量的群速度值没有统计学差异。

更新日期:2021-09-14