GULFMET EM-S3 comparison of AC-DC voltage transfer standards
Metrologia ( IF 2.4 ) Pub Date : 2021-07-09 , DOI: 10.1088/0026-1394/58/1a/01003
Mehedin Arifovic 1 , Naylan Kanatoğlu 1 , Ahmed N AlJomaie 2 , Abdullah M Alrobaish 2 , Mamdouh Halawa 3 , Eugene Golovins 4
Affiliation  

A comparison of AC-DC Voltage Transfer Standards between TBİTAK (Turkey), NMCC SASO (Saudi Arabia), NIS (Egypt) and NMISA (South Africa) conducted between February 2018 and April 2019. Fluke 792A is used as the traveling standard and TBİTAK acted as the pilot laboratory. Measurements are performed at 10 mV, 3 V @ 10 Hz, 55 Hz, 1 kHz, 20 kHz, 100 kHz and 1 MHz, and 1000 V @ 55 Hz, 1 kHz and 20 kHz.

To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/.

The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).



中文翻译:

GULFMET EM-S3 AC-DC电压传输标准对比

2018 年 2 月至 2019 年 4 月期间,TBİTAK(土耳其)、NMCC SASO(沙特阿拉伯)、NIS(埃及)和 NMISA(南非)之间的 AC-DC 电压传输标准比较。 Fluke 792A 用作旅行标准,TBİTAK担任中试实验室。测量在 10 mV、3 V @ 10 Hz、55 Hz、1 kHz、20 kHz、100 kHz 和 1 MHz 以及 1000 V @ 55 Hz、1 kHz 和 20 kHz 下进行。

要访问本文的正文,请单击最终报告。请注意,此文本出现在 BIPM 密钥比较数据库 https://www.bipm.org/kcdb/ 的附录 B 中。

根据 CIPM 互认安排 (CIPM MRA) 的规定,最终报告已通过同行评审并由 CCEM 批准发布。