Evaluating Size-Specific Dose Estimate (SSDE) as an estimate of organ doses from routine CT exams derived from Monte Carlo simulations
Medical Physics ( IF 3.2 ) Pub Date : 2021-07-26 , DOI: 10.1002/mp.15128
Anthony James Hardy 1 , Maryam Bostani 2, 3 , Grace Hyun J Kim 2 , Christopher H Cagnon 2, 3 , Maria Agnes Zankl 4 , Michael McNitt-Gray 2, 3
Affiliation  

Size-specific dose estimate (SSDE) is a metric that adjusts CTDIvol to account for patient size. While not intended to be an estimate of organ dose, AAPM Report 204 notes the difference between the patient organ dose and SSDE is expected to be 10–20%. The purpose of this work was therefore to evaluate SSDE against estimates of organ dose obtained using Monte Carlo (MC) simulation techniques applied to routine exams across a wide range of patient sizes.