The bandwidth chopper system design of the energy-resolved neutron imaging instrument at CSNS
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment ( IF 1.5 ) Pub Date : 2021-07-18 , DOI: 10.1016/j.nima.2021.165670 Zhirong Zeng 1, 2 , Jie Chen 1, 2 , Zhijian Tan 1, 2 , Chaoju Yu 1, 2 , Haibiao Zheng 1, 2 , Shengxiang Wang 1, 2 , Lunhua He 1, 3 , Tianjiao Liang 1, 2
更新日期:2021-07-23
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment ( IF 1.5 ) Pub Date : 2021-07-18 , DOI: 10.1016/j.nima.2021.165670 Zhirong Zeng 1, 2 , Jie Chen 1, 2 , Zhijian Tan 1, 2 , Chaoju Yu 1, 2 , Haibiao Zheng 1, 2 , Shengxiang Wang 1, 2 , Lunhua He 1, 3 , Tianjiao Liang 1, 2
Affiliation
An imaging beam line, Energy-Resolved Neutron Imaging instrument (ERNI) is under construction at China Spallation Neutron Source (CSNS). Here we describe the design of its bandwidth chopper system, such as the operation modes and the determination of the chopper parameters by theoretical calculations. The Monte Carlo simulations using McStas are performed to check the design of the bandwidth choppers system. The results of the theoretical calculations and the Monte Carlo simulations agree well in this work.