Evaluation of the GEANT4 transport algorithm and radioactive decay data for alpha particle dosimetry
Applied Radiation and Isotopes ( IF 1.6 ) Pub Date : 2021-07-01 , DOI: 10.1016/j.apradiso.2021.109849
Ahtesham Ullah Khan 1 , Larry A DeWerd 1
Affiliation  

A Fano cavity test was implemented in GEANT4 Monte Carlo code to evaluate the alpha particle transport algorithm. GEANT4 alpha emission data for 212Pb, 223Ra, 227Th, and 225Ac was compared with the MIRD and RADAR decay databases. Optimal electromagnetic transport parameters (dRover of 0.1 and final range of 1 μm) were recommended since the calculated results with the default parameters differed up to 4.7% from the theoretical results. Good agreement was found between the three decay databases besides a few discrepancies.



中文翻译:

α粒子剂量测定的GEANT4传输算法和放射性衰变数据的评估

在 GEANT4 Monte Carlo 代码中实施了 Fano 腔测试以评估 alpha 粒子传输算法。将212 Pb、223 Ra、227 Th 和225 Ac 的GEANT4 α 发射数据与 MIRD 和 RADAR 衰减数据库进行了比较。推荐最佳电磁传输参数(dRover为 0.1,最终范围为 1 μm),因为使用默认参数的计算结果与理论结果的差异高达 4.7%。除了一些差异之外,在三个衰减数据库之间发现了良好的一致性。