当前位置: X-MOL 学术Radiat. Protect. Dosim. › 论文详情
Our official English website, www.x-mol.net, welcomes your feedback! (Note: you will need to create a separate account there.)
ASSESSMENT OF PATIENT’S RADIATION EXPOSURES RESULTED FROM PET/CT 18F-FCH AND 68GA-PSMA PROCEDURES
Radiation Protection Dosimetry ( IF 0.8 ) Pub Date : 2021-05-10 , DOI: 10.1093/rpd/ncab077
H Salah 1, 2 , H I Al-Mohammed 3 , F H Mayhoub 4 , A Sulieman 5 , M Alkhorayef 6, 7 , Fouad A Abolaban 8 , Mayeen Uddin Khandaker 9 , D A Bradley 7, 9
Affiliation  

This study has sought to evaluate patient exposures during the course of particular diagnostic positron emission tomography and computed tomography (PET/CT) techniques. A total of 73 patients were examined using two types of radiopharmaceutical: 18F-fluorocholine (FCH, 48 patients) and 68Ga-prostate-specific membrane antigen (PSMA, 25 patients). The mean and range of administered activity (AA) in MBq, and effective dose (mSv) for FCH were 314.4 ± 61.6 (462.5–216.8) and 5.9 ± 1.2 (8.8–4.11), respectively. Quoted in the same set of units, the mean and range of AA and effective dose for 68Ga-PSMA were 179.3 ± 92.3 (603.1–115.1) and 17.9 ± 9.2 (60.3–11.5). Patient effective doses from 18F-FCH being a factor of two greater than the dose resulting from 68Ga-PSMA PET/CT procedures. CT accounts for some 84 and 23% for 18F-FCH and 68Ga-PSMA procedures, accordingly CT acquisition parameter optimization is recommended. Patient doses have been found to be slightly greater than previous studies.

中文翻译:

PET/CT 18F-FCH 和 68GA-PSMA 程序导致的患者辐射暴露评估

本研究试图评估在特定诊断正电子发射断层扫描和计算机断层扫描 (PET/CT) 技术过程中患者的暴露情况。使用两种类型的放射性药物检查了总共 73 名患者:18F-氟胆碱(FCH,48 名患者)和 68Ga-前列腺特异性膜抗原(PSMA,25 名患者)。MBq 中给药活性 (AA) 的平均值和范围以及 FCH 的有效剂量 (mSv) 分别为 314.4 ± 61.6 (462.5–216.8) 和 5.9 ± 1.2 (8.8–4.11)。引用同一组单位,AA 的平均值和范围以及 68Ga-PSMA 的有效剂量分别为 179.3 ± 92.3 (603.1–115.1) 和 17.9 ± 9.2 (60.3–11.5)。来自 18F-FCH 的患者有效剂量是 68Ga-PSMA PET/CT 程序产生的剂量的两倍。CT 占 18F-FCH 和 68Ga-PSMA 程序的 84% 和 23%,因此建议对 CT 采集参数进行优化。已发现患者剂量略高于以前的研究。
更新日期:2021-05-10