A Novel Non-Iterative Fault Location Algorithm for Transmission Line With Unsynchronized Terminal
IEEE Transactions on Power Delivery ( IF 3.8 ) Pub Date : 2021-01-25 , DOI: 10.1109/tpwrd.2021.3054235
Kaustav Kalita , Shubham Anand , S. K. Parida

This letter presents a novel non-iterative impedance based two-terminal fault location algorithm with unsynchronized terminals. The novelty of this method lies in the fact that it is non-iterative, does not require signal alignment, are independent of fault classification, suitable for both transposed and untransposed lines with distributed line model. Several results of simulations on standard and practical data of Power Grid Corporation of India Limited (PGCIL) are presented. The test results verifies the validity and accuracy of the developed fault location algorithm.

中文翻译:

终端不同步的输电线路非迭代故障测距新算法

这封信提出了一种新颖的基于非迭代阻抗且两端不同步的两端故障定位算法。该方法的新颖性在于它是非迭代的,不需要信号对准,并且与故障分类无关,适用于分布式线路模型的转置和未转置线路。给出了印度电网公司(PGCIL)的标准和实用数据的仿真结果。测试结果验证了所开发故障定位算法的有效性和准确性。