当前位置: X-MOL 学术Mater. Corros. › 论文详情
Our official English website, www.x-mol.net, welcomes your feedback! (Note: you will need to create a separate account there.)
Application of LPR and EIS techniques for on-site corrosion monitoring at the geothermal plant in Central Poland
Materials and Corrosion ( IF 1.6 ) Pub Date : 2021-04-23 , DOI: 10.1002/maco.202112340
Ewa Ura‐Bińczyk 1 , Anna Dobkowska 1 , Mariusz Andrzejczuk 1 , Agata Roguska 2 , Bogusław Mazurkiewicz 3 , Wojciech Solarski 3 , Marek Balcer 4 , Małgorzata Lewandowska 1 , Jacek Banaś 3
Affiliation  

Corrosion monitoring station was installed at ‘Geotermia Mazowiecka’ geothermal plant in Poland. Linear polarisation resistance and electrochemical impedance spectroscopy techniques were applied to estimate the corrosion rate and the surface changes of K55 carbon steel, L80-13CR and 316 stainless steels directly in the geothermal water flux. The enhanced corrosion of K55 carbon steel and corrosion rate of L80-13CR and 316 stainless steels was observed. The formation of biofilm increased the resistivity of the surface.

中文翻译:

LPR和EIS技术在波兰中部地热电厂现场腐蚀监测中的应用

腐蚀监测站安装在波兰的“Geotermia Mazowiecka”地热发电厂。应用线性极化电阻和电化学阻抗谱技术直接估计 K55 碳钢、L80-13CR 和 316 不锈钢在地热水通量中的腐蚀速率和表面变化。观察到 K55 碳钢的腐蚀增强和 L80-13CR 和 316 不锈钢的腐蚀速率。生物膜的形成增加了表面的电阻率。
更新日期:2021-04-23