当前位置: X-MOL 学术J. Geod. › 论文详情
Our official English website, www.x-mol.net, welcomes your feedback! (Note: you will need to create a separate account there.)
A broadband VLBI system using transportable stations for geodesy and metrology: an alternative approach to the VGOS concept
Journal of Geodesy ( IF 3.9 ) Pub Date : 2021-03-25 , DOI: 10.1007/s00190-021-01479-8
Mamoru Sekido , Kazuhiro Takefuji , Hideki Ujihara , Tetsuro Kondo , Masanori Tsutsumi , Eiji Kawai , Hidekazu Hachisu , Nils Nemitz , Marco Pizzocaro , Cecilia Clivati , Federico Perini , Monia Negusini , Giuseppe Maccaferri , Roberto Ricci , Mauro Roma , Claudio Bortolotti , Kunitaka Namba , Jun’ichi Komuro , Ryuichi Ichikawa , Tomonari Suzuyama , Ken-ichi Watabe , Julia Leute , Gérard Petit , Davide Calonico , Tetsuya Ido

We have developed a broadband VLBI (very long baseline interferometry) system inspired by the concept of the VLBI Global Observing System (VGOS). The new broadband VLBI system was implemented in the Kashima 34 m antenna and in two transportable stations utilizing 2.4 m diameter antennas. The transportable stations have been developed as a tool for intercontinental frequency comparison but are equally useful for geodesy. To enable practical use of such small VLBI stations in intercontinental VLBI, we have developed the procedure of node-hub style VLBI: In joint observation with a large, high sensitivity ‘hub’ antenna, the closure delay relation provides a virtual delay observable between ‘node’ stations. This overcomes the limited sensitivity of the small diameter node antennas, while error sources associated with large diameter antennas, such as gravitational deformation and delay changes in necessarily long signal cables, are eliminated. We show that this scheme does not result in an increased sensitivity to radio source structure if one side of the baseline triangle is kept short. We have performed VLBI experiments utilizing this approach over both short range and intercontinental distance. This article describes the system components, signal processing procedure, experiment, and results in terms of baseline repeatability. Our measurements reveal signatures of structure effects in the correlation amplitude of several of the observed radio sources. We present a model of the frequency-dependent source size for 1928+738 derived from correlation amplitude data observed in four frequency bands.



中文翻译:

使用可移动站进行大地测量和计量的宽带VLBI系统:VGOS概念的替代方法

我们已经根据VLBI全球观测系统(VGOS)的概念开发了宽带VLBI(超长基线干涉仪)系统。新的宽带VLBI系统在鹿岛34 m天线和两个使用2.4 m直径天线的可移动站中实现。可移动站已被开发为用于洲际频率比较的工具,但对于大地测量也同样有用。为了能够在洲际VLBI中实际使用这种小型VLBI站,我们开发了节点集线器式VLBI的程序:在与大型,高灵敏度“集线器”天线的联合观测中,闭合延迟关系提供了“节点站。这克服了小直径节点天线灵敏度有限的问题,而与大直径天线相关的误差源,消除了诸如引力变形和必然较长的信号电缆中的延迟变化之类的问题。我们表明,如果基线三角形的一侧保持较短,则该方案不会导致对无线电源结构的灵敏度提高。我们已经利用这种方法在短距离和洲际距离上进行了VLBI实验。本文以基线可重复性的方式描述了系统组件,信号处理过程,实验和结果。我们的测量揭示了几个观察到的无线电源的相关幅度中的结构效应特征。我们提出了一个1928 + 738频率相关源大小的模型,该模型源于在四个频带中观察到的相关振幅数据。被淘汰。我们表明,如果基线三角形的一侧保持较短,则该方案不会导致对无线电源结构的灵敏度提高。我们已经利用这种方法在短距离和洲际距离上进行了VLBI实验。本文以基线可重复性的方式描述了系统组件,信号处理过程,实验和结果。我们的测量揭示了几个观察到的无线电源的相关幅度中的结构效应特征。我们提出了一个1928 + 738频率相关源大小的模型,该模型源于在四个频带中观察到的相关振幅数据。被淘汰。我们表明,如果基线三角形的一侧保持较短,则该方案不会导致对无线电源结构的灵敏度提高。我们已经利用这种方法在短距离和洲际距离上进行了VLBI实验。本文以基线可重复性的方式描述了系统组件,信号处理过程,实验和结果。我们的测量揭示了几个观察到的无线电源的相关幅度中的结构效应特征。我们提出了一个1928 + 738频率相关源大小的模型,该模型源于在四个频带中观察到的相关振幅数据。我们已经利用这种方法在短距离和洲际距离上进行了VLBI实验。本文以基线可重复性的方式描述了系统组件,信号处理过程,实验和结果。我们的测量揭示了几个观察到的无线电源的相关幅度中的结构效应特征。我们提出了一个1928 + 738频率相关源大小的模型,该模型源于在四个频带中观察到的相关振幅数据。我们已经利用这种方法在短距离和洲际距离上进行了VLBI实验。本文以基线可重复性的方式描述了系统组件,信号处理过程,实验和结果。我们的测量揭示了几个观察到的无线电源的相关幅度中的结构效应特征。我们提出了一个1928 + 738频率相关源大小的模型,该模型源于在四个频带中观察到的相关振幅数据。我们的测量揭示了几个观察到的无线电源的相关幅度中的结构效应特征。我们提出了一个1928 + 738频率相关源大小的模型,该模型源于在四个频带中观察到的相关振幅数据。我们的测量揭示了几个观察到的无线电源的相关幅度中的结构效应特征。我们提出了一个1928 + 738频率相关源大小的模型,该模型源于在四个频带中观察到的相关振幅数据。

更新日期:2021-03-25
down
wechat
bug