当前位置: X-MOL 学术Ships Offshore Struct. › 论文详情
Our official English website, www.x-mol.net, welcomes your feedback! (Note: you will need to create a separate account there.)
Fire resistance of collar-plate-reinforced multi-planar tubular KK-joints: experimental and numerical study for the design formulation
Ships and Offshore Structures ( IF 1.7 ) Pub Date : 2021-03-11 , DOI: 10.1080/17445302.2021.1897233
Neda Azari-Dodaran 1 , Hamid Ahmadi 1, 2
Affiliation  

ABSTRACT

In the present paper, the fire resistance of two-planar tubular KK-joints reinforced with collar plates is studied and formulated. After establishing a finite element (FE) model and its verification against the results of experimental tests, a total of 1440 numerical simulations were performed on 360 FE models of collar-plate-stiffened two-planar tubular KK-joints at four different temperatures (20, 400, 550, and 700°C). The studied joints were analysed under the axial loading and the reinforcing effect of the collar plate was investigated. Results showed that the resistance enhancement coefficient (Rs) increases by increasing the γ, θ, and τ; while it decreases by increasing the β. Results of the parametric investigation were utilised to establish new design equations to determine the bearing capacity of collar-plate-stiffened two-planar tubular KK-joints under the brace axial loads at fire condition.



中文翻译:

卡箍板增强多平面管状 KK 接头的耐火性:设计公式的实验和数值研究

摘要

本文研究并制定了带环板加固的两平面管状 KK 接头的耐火性能。在建立有限元 (FE) 模型并根据实验测试结果对其进行验证后,对 360 个领板加筋双平面管状 KK 接头在 4 个不同温度下的 360 个有限元模型(20 、400、550 和 700°C)。对所研究的节点在轴向载荷下进行了分析,并研究了领板的加固效果。结果表明,电阻增强系数(R s)随着γθτ的增加而增加;而它随着β的增加而减小. 参数研究的结果被用来建立新的设计方程,以确定在火灾条件下支撑轴向载荷下的领板加筋双平面管状 KK 接头的承载能力。

更新日期:2021-03-11
down
wechat
bug