当前位置: X-MOL 学术Phys. Atomic Nucl. › 论文详情
Our official English website, www.x-mol.net, welcomes your feedback! (Note: you will need to create a separate account there.)
Fading Correction of Readings of Glass Gamma-Radiation Dosimeters SOPD (DTS)-0.05/10 within the Interval of Post-Irradiation Measurements from 1 to 100 Days
Physics of Atomic Nuclei ( IF 0.3 ) Pub Date : 2021-02-11 , DOI: 10.1134/s1063778820080074
A. S. Koshelev , E. Yu. Tarasova , P. Yu. Lapin , A. E. Nikiforov

Abstract

This work presents the results of experimental study of post-irradiation variation (fading) of SO PD (DTS) dosimeter readings within the interval from 1 to 100 days after radiation loading by reactor (BR-K1) and bremsstrahlung (LU-10-20) gamma quanta within the interval of absorbed doses from 50 Gy (water) to 10 kGy (water). There is advanced a formalism for fading correction of dosimeter dose readings based on the application of exponential and logarithmic forms of the functional dependence for the ratios of the light-transmission coefficient conditioned by radiation loading and its values obtained at arbitrary time points after irradiation is completed.



中文翻译:

在1到100天的辐照后测量间隔内,玻璃伽马辐射剂量计SOPD(DTS)-0.05 / 10的读数的褪色校正

摘要

这项工作提供了在反应堆(BR-K1)和致辐射(LU-10-20)加载辐射后1到100天内,SO PD(DTS)剂量计读数的辐照后变化(褪色)的实验研究结果。 )在50 Gy(水)至10 kGy(水)的吸收剂量范围内的γ量子。对于辐射剂量条件下的光透射系数的比率及其在照射完成后任意时间点获得的值的函数依赖性的指数形式和对数形式的应用,已经提出了用于剂量计剂量读数的淡入淡出校正的形式主义。