Measurement of the 27Al+ and 87Sr absolute optical frequencies
Metrologia ( IF 2.1 ) Pub Date : 2021-01-22 , DOI: 10.1088/1681-7575/abd040
Holly Leopardi 1, 2, 3 , Kyle Beloy 1 , Tobias Bothwell 4 , Samuel M Brewer 1, 2 , Sarah L Bromley 4 , Jwo-Sy Chen 1, 2 , Scott A Diddams 1, 2 , Robert J Fasano 1, 2 , Youssef S Hassan 1, 2 , David B Hume 1 , Dhruv Kedar 4 , Colin J Kennedy 1, 4 , David R Leibrandt 1, 2 , Andrew D Ludlow 1 , William F McGrew 1, 2 , William R Milner 4 , Daniele Nicolodi 1, 2 , Eric Oelker 1, 4 , Thomas E Parker 1 , John M Robinson 4 , Stefania Romisch 1 , Jeff A Sherman 1 , Lindsay Sonderhouse 4 , Jian Yao 1, 4 , Jun Ye 1, 4 , Xiaogang Zhang 1, 2 , Tara M Fortier 1, 2
Affiliation  

We perform absolute measurement of the 27Al+ single-ion and 87Sr neutral lattice clock frequencies at the National Institute of Standards and Technology and JILA at the University of Colorado against a global ensemble of primary frequency standards. Over an eight month period multiple measurements yielded the mean optical atomic transition frequencies ${\nu }_{{\text{Al}}^{+}}=1\enspace 121\enspace 015\enspace 393\enspace 207\enspace 859.50\left(0.36\right)$ Hz and ν Sr = 429 228 004 229 873.19(0.15) Hz, where the stated uncertainties are dominated by statistical noise and gaps in the observation interval (‘dead-time’ uncertainty).



中文翻译:

测量27 Al +87 Sr绝对光学频率

我们在美国国家标准技术研究院和科罗拉多大学的JILA上对27 Al +单离子和87 Sr中性点阵时钟频率进行了绝对测量,与全球主要频率标准集合进行了对比。在八个月期间多次测量得到的平均光原子跃迁频率$ {\ nu} _ {{\ text {Al}} ^ {+}} = 1 \ enspace 121 \ enspace 015 \ enspace 393 \ enspace 207 \ enspace 859.50 \ left(0.36 \ right)$赫兹和ν 的Sr = 429 228 004 229 873.19(0.15)赫兹,其中所述不确定性是由统计噪声和间隙在观测间隔支配(“死区时间”不确定)。

更新日期:2021-01-22
down
wechat
bug