当前位置: X-MOL 学术Sci. Rep. › 论文详情
Our official English website, www.x-mol.net, welcomes your feedback! (Note: you will need to create a separate account there.)
Continuous and non-invasive thermography of mouse skin accurately describes core body temperature patterns, but not absolute core temperature
Scientific Reports ( IF 3.8 ) Pub Date : 2020-11-26 , DOI: 10.1038/s41598-020-77786-5
Vincent van der Vinne , Carina A. Pothecary , Sian L. Wilcox , Laura E. McKillop , Lindsay A. Benson , Jenya Kolpakova , Shu K. E. Tam , Lukas B. Krone , Angus S. Fisk , Tatiana S. Wilson , Tomoko Yamagata , James Cantley , Vladyslav V. Vyazovskiy , Stuart N. Peirson

Body temperature is an important physiological parameter in many studies of laboratory mice. Continuous assessment of body temperature has traditionally required surgical implantation of a telemeter, but this invasive procedure adversely impacts animal welfare. Near-infrared thermography provides a non-invasive alternative by continuously measuring the highest temperature on the outside of the body (Tskin), but the reliability of these recordings as a proxy for continuous core body temperature (Tcore) measurements has not been assessed. Here, Tcore (30 s resolution) and Tskin (1 s resolution) were continuously measured for three days in mice exposed to ad libitum and restricted feeding conditions. We subsequently developed an algorithm that optimised the reliability of a Tskin-derived estimate of Tcore. This identified the average of the maximum Tskin per minute over a 30-min interval as the optimal way to estimate Tcore. Subsequent validation analyses did however demonstrate that this Tskin-derived proxy did not provide a reliable estimate of the absolute Tcore due to the high between-animal variability in the relationship between Tskin and Tcore. Conversely, validation showed that Tskin-derived estimates of Tcore reliably describe temporal patterns in physiologically-relevant Tcore changes and provide an excellent measure to perform within-animal comparisons of relative changes in Tcore.



中文翻译:

连续且无创的小鼠皮肤热成像技术可以准确描述核心体温模式,但不能描述绝对核心温度

在许多实验室小鼠研究中,体温是重要的生理参数。传统上,连续评估体温需要手术植入遥测仪,但是这种侵入性手术会对动物福利产生不利影响。近红外热成像通过连续测量人体外部(T皮肤)的最高温度提供了一种非侵入性替代方法,但是这些记录作为连续核心体温(T core)测量指标的可靠性尚未得到评估。 。在这里,T核心(30 s分辨率)和T皮肤在随意接触和限制性喂养条件下的小鼠中连续三天(1 s分辨率)进行测量。随后,我们开发了一种算法,该算法优化了T皮肤派生的T估计的可靠性。这将30分钟间隔内每分钟最大T皮肤的平均值确定为估算T core的最佳方法。然而,随后的验证分析确实表明,由于T皮肤与T核心之间的关系在动物之间存在很高的变异性,因此这种T皮肤衍生的代理无法提供绝对T核心的可靠估计。相反,验证显示T皮肤T核的估计值可靠地描述了与生理相关的T变化中的时间模式,并为进行T相对变化的动物内比较提供了极好的方法。

更新日期:2020-11-27
down
wechat
bug