Comparison of the Operating Range of a Wetted‐Wall Column with a Packed Column for Distillation
Chemie Ingenieur Technik ( IF 1.5 ) Pub Date : 2020-10-12 , DOI: 10.1002/cite.202000065 Arnulf Reitze 1 , Marcus Grünewald 1 , Julia Riese 1
Chemie Ingenieur Technik ( IF 1.5 ) Pub Date : 2020-10-12 , DOI: 10.1002/cite.202000065 Arnulf Reitze 1 , Marcus Grünewald 1 , Julia Riese 1
Affiliation
In this paper, a newly designed distillation column consisting of a wetted wall with a rectangular cross section is analyzed and compared with a conventional packed column with regard to the operating range of both apparatuses. As expected, the pressure drop is considerably lower in the wetted‐wall column and, therefore, it offers a higher range of operation. However, in the wetted‐wall column, the separation efficiency decreases rapidly with increasing F factors. This effect can be overcome by the serial connection of two wetted‐wall columns.
中文翻译:
湿壁塔与填充塔的蒸馏操作范围比较
在本文中,分析了一种新设计的蒸馏塔,该蒸馏塔由具有矩形横截面的湿壁组成,并且在两种设备的操作范围方面与常规填充塔进行了比较。如预期的那样,湿壁塔中的压降要低得多,因此,它提供了更大的操作范围。但是,在湿壁塔中,分离 系数随着F因子的增加而迅速降低。通过串联两个湿壁色谱柱可以克服这种影响。