当前位置: X-MOL 学术Eng. Fail. Anal. › 论文详情
Our official English website, www.x-mol.net, welcomes your feedback! (Note: you will need to create a separate account there.)
Failure analysis on the oxygen corrosion of the perforated screens used in a gas injection huff and puff well
Engineering Failure Analysis ( IF 4.4 ) Pub Date : 2020-10-12 , DOI: 10.1016/j.engfailanal.2020.104984
Lei Fan , Yuan Gao , Juntao Yuan , Chenxian Yin , Anqing Fu , Mifeng Zhao , Yan Li , Tao Suo , Xiaoyi Du , Yanhai Wang

The perforated screens of a gas injection huff and puff well broke down in an oilfield in western China. The physical and chemical properties of the failure-perforated screens met the requirements of relevant technical protocols. The injected gas was nitrogen produced by the membrane nitrogen method, which contains approximately 5% O2. Therefore, a substantial amount of O2 entered the well during the gas injection, and greatly promoteed the cathodic process of the electrochemical corrosion. High salinity formation water, especially with large amounts of Cl-, further accelerated the corrosion. The significant oxygen corrosion under the well finally led to the failure of the perforated screen.

更新日期:2020-10-30
down
wechat
bug