当前位置: X-MOL 学术Geothermics › 论文详情
Our official English website, www.x-mol.net, welcomes your feedback! (Note: you will need to create a separate account there.)
Well spacing of the doublet at the Huangtsuishan geothermal site, Taiwan
Geothermics ( IF 3.5 ) Pub Date : 2021-01-01 , DOI: 10.1016/j.geothermics.2020.101968
Shang-Ying Chen , Bieng-Zih Hsieh , Kuo-Chin Hsu , Yi-Fei Chang , Jia-Wei Liu , Kai-Chun Fan , Li-Wei Chiang , Yin-Lung Han

Abstract The issue of thermal breakthrough is often encountered in the extraction of geothermal fluids with reinjection. This study analyzes the minimum safe distance between doublet wells that will maintain thermal productivity under various conditions at the Huangtsuishan geothermal site. A conceptual model is constructed and hypothetical exploitation scenarios are explored. The results show that a distance of 300 m is required to avoid a thermal break in 80 years with 120 tons/hour pumped and 90 % reinjected at the Huangtsuishan Geothermal site. A regression formula was provided as a guideline for the minimum required doublet distance for various pumping rates.
更新日期:2021-01-01
down
wechat