Abstract

A method been developed for the rapid determination of bacteria on the example of E. coli cells in tap water with a slot-mode sensor in the acoustic-delay line. The method is based on the recording of changes in the depth and frequency of the resonance-absorption peaks on the frequency dependence of the output signal of the sensor before and after the infection of microbial cells with specific bacteriophages. Control experiments excluding the nonspecific interaction of microbial cells with bacteriophages were carried out. The bacterial detection limit turned out to be ~103 cells/mL with an analysis time of 5 min. A distinctive feature of the used sensor is the presence of a removable liquid container. This allows its reuse and facilitates the process of eliminating the sample from the container.