当前位置: X-MOL 学术Magn. Reson. Mater. Phy. Biol. Med. › 论文详情
Our official English website, www.x-mol.net, welcomes your feedback! (Note: you will need to create a separate account there.)
Variable echo time imaging for detecting the short T2* components of the sciatic nerve: a validation study.
Magnetic Resonance Materials in Physics Biology and Medicine ( IF 2.0 ) Pub Date : 2020-09-22 , DOI: 10.1007/s10334-020-00886-w
Paolo Florent Felisaz 1, 2 , Eugenio Belatti 1 , Xeni Deligianni 3, 4 , Niels Bergsland 5, 6 , Francesco Santini 3, 4 , Matteo Paoletti 1 , Francesca Solazzo 1 , Giancarlo Germani 1 , Andrea Cortese 7, 8 , Elisa Vegezzi 7 , Oliver Bieri 3, 4 , Stefano Bastianello 1, 7 , Anna Pichiecchio 1, 7
Affiliation  

Objective

The aim of this study was to develop and validate an MRI protocol based on a variable echo time (vTE) sensitive to the short T2* components of the sciatic nerve.

Materials and methods

15 healthy subjects (M/F: 9/6; age: 21–62) were scanned at 3T targeting the sciatic nerve at the thigh bilaterally, using a dual echo variable echo time (vTE) sequence (based on a spoiled gradient echo acquisition) with echo times of 0.98/5.37 ms. Apparent T2* (aT2*) values of the sciatic nerves were calculated with a mono-exponential fit and used for data comparison.

Results

There were no significant differences in aT2* related to side, sex, age, and BMI, even though small differences for side were reported. Good-to-excellent repeatability and reproducibility were found for geometry of ROIs (Dice indices: intra-rater 0.68–0.7; inter-rater 0.70–0.72) and the related aT2* measures (intra-inter reader ICC 0.95–0.97; 0.66–0.85) from two different operators. Side-related signal-to-noise-ratio non-significant differences were reported, while contrast-to-noise-ratio measures were excellent both for side and echo.

Discussion

Our study introduces a novel MR sequence sensitive to the short T2* components of the sciatic nerve and may be used for the study of peripheral nerve disorders.



中文翻译:

用于检测坐骨神经短 T2* 成分的可变回波时间成像:一项验证研究。

客观的

本研究的目的是开发和验证基于对坐骨神经短 T2* 成分敏感的可变回波时间 (vTE) 的 MRI 方案。

材料和方法

使用双回波可变回波时间 (vTE) 序列(基于损坏的梯度回波采集)对 15 名健康受试者(男/女:9/6;年龄:21-62)进行 3T 扫描,针对大腿两侧的坐骨神经),回波时间为 0.98/5.37 毫秒。使用单指数拟合计算坐骨神经的表观 T2* (aT2*) 值并用于数据比较。

结果

尽管据报道侧面存在微小差异,但与侧面、性别、年龄和 BMI 相关的 aT2* 没有显着差异。ROI 的几何形状(Dice 指数:评估者内 0.68–0.7;评估者间 0.70–0.72)和相关的 aT2* 测量(阅读器间 ICC 0.95–0.97;0.66– 0.85)来自两个不同的运营商。据报道,与侧面相关的信噪比没有显着差异,而侧面和回声的对比噪声比测量结果都非常出色。

讨论

我们的研究引入了一种对坐骨神经短 T2* 成分敏感的新型 MR 序列,可用于周围神经疾病的研究。

更新日期:2020-09-22
down
wechat
bug