Steady-state multiphysics analysis of stator bar using finite element method
International Journal of Applied Electromagnetics and Mechanics ( IF 0.6 ) Pub Date : 2020-09-17 , DOI: 10.3233/jae-200012
José William Ribeiro Borges 1 , Wellington da Silva Fonseca 1 , Fernando de Souza Brasil 2 , Ramon C.F. Araújo 1
Affiliation  

The electrical insulation is one of the main sources of failures in hydro-generators, therefore it is important to research the insulation system of stator bars. In this paper, it is developed a steady-state multiphysics analysis of a stator bar using the Finite Element Method to assess its steady-state behavior in the electrical, magnetic and thermal domains. Different aspects are analyzed in simulations, such as capacitance, mechanical stress and thermal effects. Numerical results are compared with experimental measurements for validation.

中文翻译:

定子棒的稳态多物理场有限元分析

电绝缘是水轮发电机故障的主要来源之一,因此研究定子棒的绝缘系统很重要。在本文中,使用有限元方法对定子棒进行了稳态多物理场分析,以评估其在电,磁和热域中的稳态行为。在仿真中分析了不同方面,例如电容,机械应力和热效应。将数值结果与实验测量值进行比较以进行验证。