Improved dynamic response strategy with dual phase-shift control for dual-active-bridge DC–DC converter
IET Power Electronics ( IF 1.7 ) Pub Date : 2020-09-14 , DOI: 10.1049/iet-pel.2020.0076
Jiazheng Sun 1 , Qiuye Sun 1 , Dazhong Ma 1 , Panfeng Wang 1
Affiliation  

In this study, an improved dynamic response strategy with dual phase-shift (IDR-DPS) for dual-active-bridge (DAB) DC–DC converter is proposed to improve system performance and eliminate DC bias caused by power mutation. Firstly, a unique combination of independent variables about inner and outer phase shift duty ratios is calculated at a given reference power through combining the minimum current stress calculation method with DPS control, which makes DAB run efficiently. On this basis, a DC bias elimination method is proposed to eliminate DC bias current in half a switching period through modifying inner duty ratios during transient process and drive DAB to reach new steady state quickly. Finally, a DAB topology platform is built to perform experiments of proposed IDR-DPS strategy and traditional direct control, the effectiveness of the proposed strategy is verified by comparative experiments.