An Adjusted Error Score Calculation for the Farnsworth-Munsell 100 Hue Test
LEUKOS ( IF 2.6 ) Pub Date : 2019-04-17 , DOI: 10.1080/15502724.2018.1514265
Tony Esposito 1
Affiliation  

ABSTRACT The Farnsworth-Munsell 100 Hue Test, a test that measures an individual’s hue discrimination ability, operates with the fundamental assumption that it is administered using a fixed, standard illuminant. This assumption is violated when the testing illuminant is changed—as is common when testing color discrimination ability of an illuminant—which likely causes a reordering of the caps in the test. To ensure that a participant is not falsely penalized for correctly responding to a hue transposition caused by the new testing light source, an adjusted error score is proposed that reconciles light source–induced hue transpositions and participant performance on the test.

中文翻译:

Farnsworth-Munsell 100 色调测试的调整误差分数计算

摘要 Farnsworth-Munsell 100 色相测试是一种测量个人色相辨别能力的测试,其运行的基本假设是使用固定的标准光源进行管理。当测试光源改变时,这个假设被违反——这在测试光源的颜色辨别能力时很常见——这可能会导致测试中的帽重新排序。为确保参与者不会因正确响应由新测试光源引起的色调换位而受到错误惩罚,建议调整误差分数,以协调光源引起的色调换位和参与者在测试中的表现。