当前位置: X-MOL 学术Eye and Vis. › 论文详情
Our official English website, www.x-mol.net, welcomes your feedback! (Note: you will need to create a separate account there.)
Characterization of the retinal vasculature in fundus photos using the PanOptic iExaminer system.
Eye and Vision ( IF 4.1 ) Pub Date : 2020-09-08 , DOI: 10.1186/s40662-020-00211-5
Huiling Hu 1, 2 , Haicheng Wei 3, 4 , Mingxia Xiao 3, 4 , Liqiong Jiang 1 , Huijuan Wang 2, 5 , Hong Jiang 2, 6 , Tatjana Rundek 6 , Jianhua Wang 2
Affiliation  

The goal was to characterize retinal vasculature by quantitative analysis of arteriole-to-venule (A/V) ratio and vessel density in fundus photos taken with the PanOptic iExaminer System. The PanOptic ophthalmoscope equipped with a smartphone was used to acquire fundus photos centered on the optic nerve head. Two fundus photos of a total of 19 eyes from 10 subjects were imaged. Retinal vessels were analyzed to obtain the A/V ratio. In addition, the vessel tree was extracted using deep learning U-NET, and vessel density was processed by the percentage of pixels within vessels over the entire image. All images were successfully processed for the A/V ratio and vessel density. There was no significant difference of averaged A/V ratio between the first (0.77 ± 0.09) and second (0.77 ± 0.10) measurements (P = 0.53). There was no significant difference of averaged vessel density (%) between the first (6.11 ± 1.39) and second (6.12 ± 1.40) measurements (P = 0.85). Quantitative analysis of the retinal vasculature was feasible in fundus photos taken using the PanOptic ophthalmoscope. The device appears to provide sufficient image quality for analyzing A/V ratio and vessel density with the benefit of portability, easy data transferring, and low cost of the device, which could be used for pre-clinical screening of systemic, cerebral and ocular diseases.

中文翻译:


使用 PanOptic iExaminer 系统表征眼底照片中的视网膜脉管系统。



目标是通过对 PanOptic iExaminer 系统拍摄的眼底照片中的小动脉与小静脉 (A/V) 比率和血管密度进行定量分析来表征视网膜血管系统。使用配备智能手机的 PanOptic 检眼镜来获取以视神经乳头为中心的眼底照片。拍摄了 10 名受试者总共 19 只眼睛的两张眼底照片。分析视网膜血管以获得 A/V 比。此外,使用深度学习U-NET提取血管树,并通过血管内像素占整个图像的百分比来处理血管密度。所有图像均已成功处理 A/V 比和血管密度。第一次 (0.77 ± 0.09) 和第二次 (0.77 ± 0.10) 测量之间的平均 A/V 比没有显着差异 (P = 0.53)。第一次 (6.11 ± 1.39) 和第二次 (6.12 ± 1.40) 测量之间的平均血管密度 (%) 没有显着差异 (P = 0.85)。在使用 PanOptic 检眼镜拍摄的眼底照片中,对视网膜血管系统进行定量分析是可行的。该设备似乎可以为分析 A/V 比和血管密度提供足够的图像质量,并且具有便携性、数据传输方便和设备成本低的优点,可用于全身、脑和眼部疾病的临床前筛查。
更新日期:2020-09-09
down
wechat
bug