Polyimide Substrates Pre-Treated by Capacitively Coupled Plasma and Coated with Composites of Tetracycline-Imprinted Polymethacrylates and Quantum Dots as Fluorescent Sensors
Journal of Analytical Chemistry ( IF 1.0 ) Pub Date : 2020-09-03 , DOI: 10.1134/s1061934820090063 Ching-Bin Ke , Jian-Lian Chen
中文翻译:
电容耦合等离子体预处理的聚酰亚胺基材,并涂有四环素印迹聚甲基丙烯酸甲酯和量子点的复合材料作为荧光传感器
更新日期:2020-09-03
Journal of Analytical Chemistry ( IF 1.0 ) Pub Date : 2020-09-03 , DOI: 10.1134/s1061934820090063 Ching-Bin Ke , Jian-Lian Chen
Abstract
After optimization of fabrication conditions, the capacitively coupled plasma-treated polyimide (PI) substrates were coated with composites of molecularly imprinted polymers and CdTe quantum dots and used to detect tetracycline (Tc) in the range of 5–3000 μM (R2 = 0.9995) with a LOD of 0.2 μM (S/N = 3, RSD = 2.2% at 5 μM Tc, n = 10) by using a fluorescent quenching effect. The selectivity of the stripped PIs was evaluated by the imprinting factors (IFs) for Tc (IF = 7.2), other Tc analogues (IF = 3.4–5.3), and steroids (IF ≈ 1) and by the recoveries of 5 μM Tc from bovine serum albumin at 300 μg/mL (98%, RSD = 3.2%, n = 5), fetal bovine serum at 1.5 ppt (98%, RSD = 2.8%, n = 5), and liquid milk (94.5%, RSD = 5.3%, n = 5).中文翻译:
电容耦合等离子体预处理的聚酰亚胺基材,并涂有四环素印迹聚甲基丙烯酸甲酯和量子点的复合材料作为荧光传感器