当前位置: X-MOL 学术X-Ray Spectrom. › 论文详情
Our official English website, www.x-mol.net, welcomes your feedback! (Note: you will need to create a separate account there.)
Improving signal‐to‐noise ratio for the forensic analysis of glass using micro X‐ray fluorescence spectrometry
X-Ray Spectrometry ( IF 1.5 ) Pub Date : 2020-08-02 , DOI: 10.1002/xrs.3179
Ruthmara Corzo 1 , Eric Steel 1
Affiliation  

Micro X‐ray fluorescence spectrometry (μXRF) is a standard technique used for the elemental analysis of glass fragments in forensic casework. The glass specimens encountered in casework are usually small (<1 mm), thin fragments that are partially transparent to the exciting X‐ray beam. In addition to providing fluorescence from the small glass fragments, the primary beam X‐rays can scatter within the chamber and provide noise in the measurements. To reduce scatter from the sample stage, the fragments are typically mounted on a thin plastic film and raised on an XRF sample cup (≤3 cm in height). However, at these heights, there may still be significant scatter from the sample stage, which adversely affects the signal‐to‐noise ratio (SNR) and the limit of detection (LOD). A plastic mount was designed and 3D‐printed in‐house to allow fragments to be raised as high as possible from the sample stage, thereby minimizing stage scatter. Most elements detected in glass showed an improvement in the SNR when using the 3D‐printed mount for analyses. The greatest improvement (>30%) was observed for lower atomic number elements (Na and Mg) and higher atomic number elements (Sr and Zr). Another simple method to improve SNR is the use of primary beam filters; when using primary beam filters during analyses, elements with characteristic lines in the high‐energy range (Rb, Sr, and Zr) showed the greatest improvement (>70%) in SNR. The impact of both strategies for the improvement of SNR is presented here.

中文翻译:

使用微X射线荧光光谱法提高玻璃法医分析的信噪比

显微X射线荧光光谱法(μXRF)是用于法医案件中玻璃碎片元素分析的标准技术。案例工作中遇到的玻璃样品通常是小的(<1 mm)细小碎片,对于激发X射线束而言部分透明。除了从小玻璃碎片中发出荧光外,主光束X射线还会在室内散射,并在测量中产生噪声。为了减少样品台的散射,通常将碎片安装在塑料薄膜上,并抬高到XRF样品杯(高度≤3 cm)上。但是,在这些高度下,样品台仍可能存在明显的散射,这会对信噪比(SNR)和检测限(LOD)产生不利影响。设计了一个塑料支架,并在内部进行3D打印,以使碎片从样品台中尽可能高地升起,从而最大程度地减少了样品台的散布。使用3D打印的安装座进行分析时,玻璃中检测到的大多数元素均显示出SNR的改善。对于较低原子序数元素(Na和Mg)和较高原子序数元素(Sr和Zr),观察到最大的改进(> 30%)。改善SNR的另一种简单方法是使用主光束滤波器。在分析过程中使用初级光束滤波器时,具有高能范围(Rb,Sr和Zr)特征线的元素在SNR方面表现出最大的改进(> 70%)。此处介绍了这两种策略对提高SNR的影响。使用3D打印的支架进行分析时,玻璃中检测到的大多数元素均显示出SNR的改善。对于较低原子序数元素(Na和Mg)和较高原子序数元素(Sr和Zr),观察到最大的改进(> 30%)。改善SNR的另一种简单方法是使用主光束滤波器。在分析过程中使用初级光束滤波器时,具有高能范围(Rb,Sr和Zr)特征线的元素在SNR方面表现出最大的改进(> 70%)。此处介绍了这两种策略对提高SNR的影响。使用3D打印的安装座进行分析时,玻璃中检测到的大多数元素均显示出SNR的改善。对于较低原子序数元素(Na和Mg)和较高原子序数元素(Sr和Zr),观察到最大的改进(> 30%)。改善SNR的另一种简单方法是使用主光束滤波器。在分析过程中使用初级光束滤波器时,具有高能范围(Rb,Sr和Zr)特征线的元素在SNR方面表现出最大的改进(> 70%)。此处介绍了这两种策略对提高SNR的影响。改善SNR的另一种简单方法是使用主光束滤波器。在分析过程中使用初级光束滤波器时,具有高能范围(Rb,Sr和Zr)特征线的元素在SNR方面表现出最大的改进(> 70%)。此处介绍了这两种策略对提高SNR的影响。改善SNR的另一种简单方法是使用主光束滤波器。在分析过程中使用初级光束滤波器时,具有高能范围(Rb,Sr和Zr)特征线的元素在SNR方面表现出最大的改进(> 70%)。此处介绍了这两种策略对提高SNR的影响。
更新日期:2020-08-02