Low Gain Avalanche Detectors for the HADES reaction time (T $$_0$$ 0 ) detector upgrade
The European Physical Journal A ( IF 2.6 ) Pub Date : 2020-07-15 , DOI: 10.1140/epja/s10050-020-00186-w
J. Pietraszko , T. Galatyuk , V. Kedych , M. Kis , W. Koenig , M. Koziel , W. Krüger , R. Lalik , S. Linev , J. Michel , S. Moneta , A. Rost , A. Schemm , C. J. Schmidt , K. Sumara , M. Träger , M. Traxler , Ch. Wendisch

Low Gain Avalanche Detector (LGAD) technology has been used to design and construct prototypes of time-zero detector for experiments utilizing proton and pion beams with High Acceptance Di-Electron Spectrometer (HADES) at GSI Darmstadt, Germany. LGAD properties have been studied with proton beams at the COoler SYnchrotron facility in Jülich, Germany. We have demonstrated that systems based on a prototype LGAD operated at room temperature and equipped with leading-edge discriminators reach a time precision below 50 ps. The application in the HADES, experimental conditions, as well as the test results obtained with proton beams are presented.

中文翻译:

低增益雪崩探测器用于HADES反应时间(T $$ _ 0 $$ 0)探测器升级

低增益雪崩探测器(LGAD)技术已被用于设计和构造零时探测器的原型,用于在德国GSI达姆施塔特(DSI)的高接受度双电子光谱​​仪(HADES)的情况下利用质子和介子束进行实验。LGAD的性质已在德国Jülich的COoler SYnchrotron设施中用质子束进行了研究。我们已经证明,基于LGAD原型的系统在室温下运行并配备了先进的鉴别器,其时间精度低于50 ps。介绍了在HADES中的应用,实验条件以及质子束获得的测试结果。