ESTIMATION OF HP(3) AMONG STAFF MEMBERS IN TWO NUCLEAR MEDICINE UNITS IN FINLAND.
Radiation Protection Dosimetry ( IF 0.8 ) Pub Date : 2020-07-14 , DOI: 10.1093/rpd/ncaa096
C Lindholm 1 , A Pekkarinen 1, 2, 3 , O Sipilä 4 , A-L Manninen 5, 6 , M Lehtinen 1 , T Siiskonen 1
Affiliation  

The eye lens exposure among 16 technicians in two nuclear medicine departments at university hospitals in Finland was investigated by measuring the operational quantity Hp(3) using EYE-D dosemeters. For all workers, the annual mean Hp(3) was estimated to be 1.1 mSv (max. 3.9 mSv). The relation between Hp(3) to routinely monitored personal dose equivalent Hp(10) was clearly correlated. Considering individual dose measurement periods (2–4 weeks), the Hp(3)/Hp(10) ratio was 0.7 (Pearson’s coefficient r = 0.90, p < 0.001, variation of ratio 0.1–2.3). The variation decreased considerably with increasing Hp(10) (σ2 = 0.04 vs. 0.43 for Hp(10) > 0.1 mSv vs. < 0.1 mSv, respectively), i.e. higher Hp(10) predicts Hp(3) more reliably. Moreover, annual Hp(10) data from national dose register during 2009–2018 were used to derive the annual Hp(3) applying the Hp(3)/Hp(10) ratio. The data from Finnish nuclear medicine departments imply that routine measurements of Hp(3) among nuclear medicine technicians are not justified.

中文翻译:

芬兰两个核医学单位工作人员中HP(3)的估算。

通过使用EYE-D剂量计测量操作量H p(3),调查了芬兰大学医院两个核医学科室的16名技术员的眼镜暴露情况。对于所有工人,年平均H p(3)估计为1.1 mSv(最大3.9 mSv)。H p(3)与常规监测的个人剂量当量H p(10)之间的关系明确相关。考虑到单独的剂量测量周期(2-4周),H p(3)/ H p(10)的比率为0.7(皮尔森系数r  = 0.90,p  <0.001,比率为0.1-2.3)。随着H p的增加,变化明显减小(10)(σ 2  = 0.04相对于0.43用于h p(10)> 0.1毫与<0.1毫,分别地),即,较高ħ p(10)预测ħ p(3)更可靠。此外,使用2009-2018年国家剂量登记表中的年度H p(10)数据,应用H p(3)/ H p(10)比率得出年度H p(3)。芬兰核医学部门的数据表明,核医学技术人员对H p(3)进行常规测量是不合理的。
更新日期:2020-08-29
down
wechat
bug