当前位置: X-MOL 学术Sens. Actuators A Phys. › 论文详情
Our official English website, www.x-mol.net, welcomes your feedback! (Note: you will need to create a separate account there.)
Low frequency ultrasonic guided waves excitated by Galfenol Rod Ultrasonic Transducer in plate inspection
Sensors and Actuators A: Physical ( IF 4.1 ) Pub Date : 2020-07-06 , DOI: 10.1016/j.sna.2020.112196
Xiaoyu Wang , Sijia Gao , Hailong Liu , Jian Li

Lower frequency ultrasonic guided wave (20 kHz–200 kHz) has obvious advantages in large area plate monitoring. It enables longer propagation distances because of low attenuation and simple modes. The present study utilized a Galfenol Rod Ultrasonic Transducer (GRUT) excite low-frequency ultrasonic guided waves in plate inspection. It was verified by finite element simulation and experiment that GRUT can excite S0 mode Lamb wave, A0 mode Lamb wave and SH0 wave. A defects detection method based on A0 mode and S0 mode Lamb wave is proposed that “A0 mode Lamb wave is used for defect determination by its amplitude variation in time domain, and utilized S0 mode Lamb wave to locate the defect”. In this paper, utilize GRUT to detect a via hole with a radius of 2 cm, the experimental results show that the proposed method is convenient and fast with less signal processing, and the experimental error is 10.22 %.



中文翻译:

Galfenol棒式超声换能器激发的低频超声导波板检测

低频超声导波(20 kHz–200 kHz)在大面积板监测中具有明显的优势。由于低衰减和简单模式,它可以实现更长的传播距离。本研究利用Galfenol棒式超声换能器(GRUT)在板检测中激发低频超声导波。通过有限元模拟和实验证明,GRUT可以激发S 0型兰姆波,A 0型兰姆波和SH 0波。提出了一种基于A 0模式和S 0模式兰姆波的缺陷检测方法,即“通过使用A 0模式兰姆波在时域中的幅度变化来确定缺陷,并利用S 0模式兰姆波定位缺陷”。本文利用GRUT技术对半径为2 cm的通孔进行检测,实验结果表明,该方法简便,快速,信号处理量少,实验误差为10.22%。