当前位置: X-MOL 学术Opt. Fiber Technol. › 论文详情
Our official English website, www.x-mol.net, welcomes your feedback! (Note: you will need to create a separate account there.)
Influence of temperature on the refractive index sensor based on a core-offset in-line fiber Mach-Zehnder interferometer
Optical Fiber Technology ( IF 2.6 ) Pub Date : 2020-09-01 , DOI: 10.1016/j.yofte.2020.102293
Fangda Yu , Baisheng Liu , Qingyu Zou , Peng Xue , Jie Zheng

Abstract The influence of temperature on a refractive index (RI) sensor based on an in-line fiber Mach-Zehnder interferometer (MZI) was investigated in both simulation and experiment. The RI sensing performance of the sensor was investigated at different temperature (25–60 °C) over an RI range of 1.33–1.37, and the RI sensitivity of the sensor was around −20.00 nm/RIU at different temperature. The results showed that the temperature variation led to a RI deviation in the RI measurement, but hardly affect the RI sensitivity. To eliminate the RI deviation in the measurement, the RI correction was given.

中文翻译:

温度对基于纤芯偏移在线光纤Mach-Zehnder干涉仪的折射率传感器的影响

摘要 通过仿真和实验研究了温度对基于在线光纤马赫-曾德干涉仪 (MZI) 的折射率 (RI) 传感器的影响。在 1.33-1.37 的 RI 范围内,在不同温度(25-60 °C)下研究了传感器的 RI 传感性能,传感器的 RI 灵敏度在不同温度下约为 -20.00 nm/RIU。结果表明,温度变化导致 RI 测量中的 RI 偏差,但几乎不影响 RI 灵敏度。为了消除测量中的 RI 偏差,给出了 RI 校正。