Abstract Central receiver is a key part of concentrating solar power tower plants, as it is not only responsible for the highly effective absorption of incident energy from the heliostat field, but also for efficient energy conversion from light to heat. Its performance will directly affect the system efficiency and generating capacity of the whole plant. In this paper, a comprehensive model of molten salt receiver, which uses the mult-section lumped parameter method, is clearly developed based on a molten salt solar power tower plant. In order to improve the reliability as well as the prediction accuracy of the developed model, the dynamic characteristics of the molten salt receiver are fully investigated by a step disturbance of external parameters. Besides, in order to improve the design level of molten salt receiver, the influence of key parameters on the performance of receiver system is also extensively studied. The results show that the incident solar flux, wind speed and absorptivity of heat-absorbing tube can greatly affect the performance of molten salt receiver system. In order to verify the validity of proposed model, the simulation results are compared with the published experimental data, and the results show the model has a high accuracy. Conclusions of this paper are good references for the design, control and commissioning of molten salt receiver systems.

中文翻译:

聚光太阳能塔式电站熔盐接收器建模与参数研究

摘要 中央接收器是太阳能塔式聚光发电厂的关键部件,它不仅负责高效吸收定日镜场入射能量,还负责将光能高效转换为热能。其性能将直接影响整个装置的系统效率和发电量。在本文中,基于熔盐太阳能塔式电站,使用多段集总参数方法明确地开发了熔盐接收器的综合模型。为了提高所建立模型的可靠性和预测精度,通过外部参数的阶跃扰动,充分研究了熔盐接收器的动态特性。此外,为了提高熔盐接收器的设计水平,关键参数对接收机系统性能的影响也得到了广泛的研究。结果表明,入射光通量、风速和吸热管的吸收率对熔盐接收系统的性能有很大影响。为了验证所提模型的有效性,将仿真结果与公开的实验数据进行了对比,结果表明该模型具有较高的精度。本文的结论为熔盐接收器系统的设计、控制和调试提供了很好的参考。将仿真结果与公开的实验数据进行对比,结果表明该模型具有较高的精度。本文的结论为熔盐接收器系统的设计、控制和调试提供了很好的参考。将仿真结果与公开的实验数据进行对比,结果表明该模型具有较高的精度。本文的结论为熔盐接收器系统的设计、控制和调试提供了很好的参考。
更新日期:2020-06-01
down
wechat
bug