REASONABLE TESTING OF HYPERGOLIC FUELS
Acta Astronautica ( IF 3.1 ) Pub Date : 2020-11-01 , DOI: 10.1016/j.actaastro.2020.02.053
S.V. Khomik , S.V. Usachev , S.P. Medvedev , A.N. Ivantsov , S.V. Stovbun , V.N. Mikhalkin , G.L. Agafonov

Abstract The paper presents the results of drop tests performed to measure ignition delay for ionic liquids under various experimental conditions. Factors that strongly affect correct determination of ignition delay are indicated. Processes preceding ignition upon contact between various quantities of a fuel and an oxidizer are explained. It is argued that well-defined experimental conditions are required to ensure correct comparison when using benchmark fuels.

中文翻译:

高乙醇燃料的合理测试

摘要 本文介绍了在各种实验条件下为测量离子液体的点火延迟而进行的跌落测试的结果。指出了强烈影响正确确定点火延迟的因素。解释了在不同数量的燃料和氧化剂接触时点火之前的过程。有人认为,在使用基准燃料时,需要明确定义的实验条件以确保正确比较。