Clinical Oral Investigations ( IF 3.1 ) Pub Date : 2020-02-07 , DOI: 10.1007/s00784-020-03235-2 Corinne E Oeschger 1, 2 , Dieter D Bosshardt 3 , Stefan Roehling 4, 5, 6 , Michael Gahlert 6, 7, 8 , David L Cochran 5 , Simone F M Janner 1, 5
Objectives
To evaluate the crestal bone response to a two-piece zirconia implant compared with a control titanium implant using periapical radiographs (PAs) and histometry.
Materials and methods
Thirty zirconia and 30 titanium implants were placed in healed posterior mandibles of five canines. Full-ceramic single-tooth restorations were cemented after 6 weeks of healing. Three observers measured the distance between the implant shoulder and the crestal bone (DIB) at placement, loading, and harvesting after 4 or 16 weeks in function. The influence of implant material and loading time on DIB as well as the inter-observer agreement were analyzed. Additionally, histometric distance between implant shoulder and most coronal bone-to-implant contact (IS-cBIC) was compared with DIB.
Results
Mean DIB values increased between 4 and 16 weeks of loading for both zirconia (from 1.66 to 2.25 mm; P < 0.0001) and titanium (from 1.81 to 1.95 mm; P = 0.06). Zirconia yielded mean IS-cBIC values of 2.18 mm and 2.48 mm (P < 0.001) and titanium 2.23 mm and 2.34 mm (P = 0.27) after 4 and 16 weeks, respectively. The raters reached an excellent intraclass correlation coefficient. PAs underestimated the bone loss on average by 0.39 mm.
Conclusions
Zirconia implants showed a greater increase of DIB during early healing and function than titanium.
Clinical relevance
Crestal peri-implant tissue dimensions may show more pronounced changes around two-piece zirconia implants during early healing. PAs may underestimate peri-implant bone loss.
中文翻译:
顶骨对负载的氧化锆和钛植入物的反应:犬的放射线照相和组织学分析。
目标
为了评估using骨对两件式氧化锆植入物与对照组钛植入物的反应,使用根尖X线片(PAs)和组织测定法。
材料和方法
将三十个氧化锆和30个钛植入物放置在五个犬牙的后牙下颌中。愈合6周后,将全瓷单齿修复体固定。三名观察者在功能放置4或16周后,在植入,装载和收获时测量了植入物肩部与牙骨(DIB)之间的距离。分析了植入物材料和加载时间对DIB的影响以及观察者之间的协议。此外,将种植体肩部和大多数冠状骨与种植体之间的接触距离(IS-cBIC)与DIB进行了比较。
结果
氧化锆(从1.66到2.25 mm;P <0.0001)和钛(从1.81到1.95 mm;P = 0.06)的平均DIB值在加载4到16周之间增加。 4周和16周后,氧化锆的平均IS-cBIC值分别为2.18 mm和2.48 mm(P <0.001)和钛2.23 mm和2.34 mm(P = 0.27)。评估者达到了极好的类内相关系数。PA将骨损失平均低估了0.39 mm。
结论
与钛相比,氧化锆植入物在早期愈合和功能方面显示出更大的DIB增加。
临床相关性
在早期愈合过程中,植入物周围组织的晶体尺寸可能会在两件式氧化锆植入物周围显示出更明显的变化。PAs可能低估了种植体周围的骨质流失。