Proton irradiation tests of single crystal diamond detector at CIAE
Nuclear Materials and Energy ( IF 2.3 ) Pub Date : 2020-02-05 , DOI: 10.1016/j.nme.2020.100735
You-hang Liu , Chang-wei Loh , Jia-liang Zhang , Fang-liang Wu , Ming Qi , Li-fu Hei , Fan-xiu Lv , Yin-long Lv , Tao Ge , Yao-qian Li , Zhen-hui Fu

Single crystal diamond (SCD) detector is considered a candidate for the upgrade of Forward Calorimeter (FCal) in the foreseen HL-LHC. In order to investigate their radiation hardness, two SCD detectors were irradiated with 100 MeV protons up to the fluence of 1.6 × 1017 protons/cm2 and their response current was measured continuously. At the end of the irradiation period, the diamond detector could still maintain function and its residual signal reduced to 5% of the initial value approximately. The maximum response current of diamond detectors exceeded one milliampere under the irradiation of one-microampere proton current. In addition, a statistical theory is presented in an attempt to obtain the best fitting curve of the response of diamond detectors.



中文翻译:

CIAE单晶金刚石探测器的质子辐照测试

单晶金刚石(SCD)检测器被认为是可预见的HL-LHC中正向量热仪(FCal)升级的候选产品。为了研究其辐射硬度,用100 MeV质子辐照了两个SCD检测器,其通量达1.6×10 17质子/ cm 2,并连续测量了它们的响应电流。在辐照期结束时,钻石探测器仍然可以保持功能,其残留信号大约减少到初始值的5%。在1微安的质子电流的照射下,金刚石探测器的最大响应电流超过1毫安。此外,提出了一种统计理论,试图获得最佳的钻石探测器响应曲线。