当前位置: X-MOL 学术Graefes Arch. Clin. Exp. Ophthalmol. › 论文详情
Our official English website, www.x-mol.net, welcomes your feedback! (Note: you will need to create a separate account there.)
Can a contact lens sensor predict the success of trabectome surgery?
Graefe's Archive for Clinical and Experimental Ophthalmology ( IF 2.4 ) Pub Date : 2020-01-03 , DOI: 10.1007/s00417-019-04576-9
Naoki Tojo 1 , Atsushi Hayashi 1
Affiliation  

PURPOSE We examined whether a contact lens sensor (CLS) is useful for the postoperative evaluation of trabectome surgery. We investigated the correlations between the outcomes of trabectome surgery and the output of a CLS. METHODS We examined 24 consecutive eyes of patients with pseudo-exfoliation glaucoma. In each eye, the intraocular pressure (IOP) fluctuations over 24 h were measured with the SENSIMED Triggerfish CLS before and at 3 months after the trabectome surgery. We divided the patients into success (n = 12 eyes) and failure (n = 12 eyes) groups; success was defined as a postoperative IOP level ≤ 21 mmHg plus an IOP reduction ≥ 20% relative to the preoperative IOP value with or without anti-glaucoma medications. We investigated CLS parameters that correlate with surgical outcomes by performing a Cox hazard regression analysis. We determined the maximum value, minimum value, and range of IOP fluctuation as CLS parameters. RESULTS The mean follow-up period was 38.0 ± 3.0 months. The success rate was 50%. The postoperative range of IOP fluctuation during the nocturnal period with the CLS was significantly correlated with the surgical results (p = 0.024). CONCLUSIONS A smaller range of IOP fluctuation was significantly correlated with better surgical outcomes. We were able to predict the surgical success after trabectome surgery at 3 months using the CLS. Thus, CLS results could be a new surgical evaluation parameter.

中文翻译:

角膜接触镜传感器可以预测截肢手术的成功吗?

目的我们检查了隐形眼镜传感器(CLS)是否可用于对手术切除的术后评估。我们调查了行截肢手术的结果和CLS的输出之间的相关性。方法我们检查了24名假脱落性青光眼患者的连续眼睛。每只眼睛在切线术手术前后和术后3个月用SENSIMED Triggerfish CLS测量24小时内的眼压(IOP)波动。我们将患者分为成功组(n = 12眼)和失败组(n = 12眼)。成功的定义是相对于术前IOP值≤21 mmHg加上术后IOP降低≥20%(无论是否使用抗青光眼药物)。我们通过进行Cox风险回归分析研究了与手术结果相关的CLS参数。我们将IOP波动的最大值,最小值和范围确定为CLS参数。结果平均随访时间为38.0±3.0个月。成功率为50%。夜间CLS时IOP的术后波动范围与手术结果显着相关(p = 0.024)。结论较小的眼压波动范围与手术效果更好相关。使用CLS,我们能够预测在3个月的行截骨手术后的手术成功率。因此,CLS结果可能是一个新的手术评估参数。夜间CLS引起的IOP波动的术后范围与手术结果显着相关(p = 0.024)。结论较小的眼压波动范围与手术效果更好相关。使用CLS,我们能够预测在3个月的行截骨手术后的手术成功率。因此,CLS结果可能是一个新的手术评估参数。夜间CLS引起的IOP波动的术后范围与手术结果显着相关(p = 0.024)。结论较小的眼压波动范围与手术效果更好相关。使用CLS,我们能够预测在3个月的行截骨手术后的手术成功率。因此,CLS结果可能是一个新的手术评估参数。
更新日期:2020-01-04