Optimization of intravoxel incoherent motion (IVIM): variability of parameters measurements using a reduced distribution of b values for breast tumors analysis.
Magnetic Resonance Materials in Physics Biology and Medicine ( IF 2.0 ) Pub Date : 2019-09-30 , DOI: 10.1007/s10334-019-00779-7
Natacha Raissa Doudou 1, 2 , Yajie Liu 2 , Sylvanus Kampo 3 , Kai Zhang 2 , Yue Dai 2 , Shaowu Wang 1, 2
Affiliation  

OBJECTIVES This study aimed to examine the variability of intravoxel incoherent motion measurements acquired from reduced distributions of b values for breast tumors analysis. MATERIALS AND METHODS The investigations were carried out on twenty-four patients with diagnosed breast tumors. A conventional unenhanced MRI and various IVIM series preset with different distributions of b values (0-1000 s/mm2) were performed. We assessed the variability in Dslow, Dfast, and PF measurements for different distributions of 9 to 4 b values compared with the IVIM metrics for 10 b values using Wilcoxon-Signed rank test. The data was statistically significant at P < 0.05. RESULTS The results showed no significant variation in the estimations of IVIM parameters in patients. However, the measurements acquired with the combination of 5 b values Showed some variation in Dfast (P = 0.028) compared with 10 b values. The data showed high wCVs in the measurements acquired using the reduced set of 6 b values for Dslow and PF and with the combination of 7 b values for Dfast. There were inconsistencies noticed in the measurements acquired from malignant tumors using reduced distributions of b values (9 b values-4 b values). However, the set of 4 b values displayed the lowest wCVs for both benign and malignant datasets. We also observed unsystematic correlations among different combinations of b values in the categories of IVIM parameters. CONCLUSION There was no relevant variation in the parameters measurements irrespective of the number of b values used. Reduced distributions of b values may find use in estimations of IVIM parameters for breast lesions analysis.

中文翻译:

体内体素不连贯运动(IVIM)的优化:使用减少的b值分布进行乳腺肿瘤分析的参数测量可变性。

目的本研究旨在检查从减少的b值分布中获取的体素不相干运动测量结果的变异性,以进行乳腺肿瘤分析。材料与方法对24名确诊为乳腺肿瘤的患者进行了研究。执行了常规的未增强MRI和预设的b值(0-1000 s / mm2)不同分布的各种IVIM系列。我们使用Wilcoxon-Signed秩和检验评估了9s至4b值的不同分布在Dslow,Dfast和PF测量中的变异性,而对于10b值的IVIM度量则进行了评估。数据在P <0.05时具有统计学意义。结果结果表明,患者的IVIM参数估计值无明显变化。然而,与5 b值组合获得的测量结果显示,与10 b值相比,Dfast有所变化(P = 0.028)。数据显示,使用Dslow和PF的6b值的缩减集以及Dfast的7b值的组合,获得的测量值具有较高的wCV。使用减少的b值分布(9 b值-4 b值)从恶性肿瘤获得的测量结果中发现存在不一致之处。但是,这组4 b值显示了良性和恶性数据集的最低wCV。我们还观察到IVIM参数类别中b值的​​不同组合之间的非系统相关性。结论无论所用b值的数量如何,参数测量值均无相关变化。