当前位置: X-MOL 学术Bio-Medical Mater. Eng. › 论文详情
Our official English website, www.x-mol.net, welcomes your feedback! (Note: you will need to create a separate account there.)
Experimental analysis of the quality of an implant embedded in the bone based on its mechanical parameters.
Bio-Medical Materials and Engineering ( IF 1 ) Pub Date : 2019-02-12 , DOI: 10.3233/bme-191043
Marcin Zaczyk 1
Affiliation  

BACKGROUND/OBJECTIVE We present a description of an experiment in which the parameters describing the quality of the mandrel embedding an implant into a bone were determined. A method was developed that allows, from outside a living organism, the strength of the mandrel of the implant in the bone tissue to be determined. Using the proposed technique, we investigated how the mechanical properties of the bone affect the quality of the implant mandrel embedding in the bone tissue. MATERIALS AND METHODS As part of the research work, we conducted 15 compression tests on previously prepared samples that reflected an uncemented endoprosthesis embedding in the proximal base of a femur bone. RESULTS The results of the research showed that the load applied is dispersed between the mandrel and the bone tissue. The mechanical stability of the embedding affects the mechanical properties of the bone. The experiment revealed the nature of the mechanical stability of the embedding in relation to the increasing contact surface area. CONCLUSIONS We observed a non-linear nature of dependences of bone density as the main parameter describing the properties of bone relative to the extent of loosening expressed in the form of the slip surface of the mandrel relative to the bone. The mechanical stability of the embedding is crucial in the initial phase of the implant healing because it eliminates the loosening of the mandrel embedding. It provides a guarantee that the specific geometry of the treated motion apparatus part will be preserved and lowers the risk of inflammatory conditions during the treatment process.

中文翻译:

根据植入物的机械参数对植入物的质量进行实验分析。

背景技术/目的我们描述了一个实验,其中确定了描述将植入物嵌入骨中的心轴质量的参数。已开发出一种方法,该方法可以从活生物体外部确定骨组织中植入物的心轴强度。使用提出的技术,我们研究了骨骼的机械性能如何影响嵌入到骨骼组织中的植入物心轴的质量。材料和方法作为研究工作的一部分,我们对预先准备的样品进行了15次压缩测试,这些样品反映出未粘结的假体嵌入股骨近端基部。结果研究结果表明,施加的载荷分散在心轴和骨组织之间。嵌入物的机械稳定性会影响骨骼的机械性能。实验揭示了嵌入物的机械稳定性与增加的接触表面积有关的性质。结论我们观察到骨密度依赖性的非线性特性,它是描述骨的特性的主要参数,相对于以心轴相对于骨的滑动表面的形式表示的松动程度。在植入物愈合的初始阶段,嵌入物的机械稳定性至关重要,因为它消除了心轴嵌入物的松动。它保证了被治疗的运动器械部件的特定几何形状将得以保留,并降低了治疗过程中发炎的风险。实验揭示了嵌入物的机械稳定性与增加的接触表面积有关的性质。结论我们观察到骨密度依赖性的非线性特性,它是描述骨的特性的主要参数,相对于以心轴相对于骨的滑动表面的形式表示的松动程度。在植入物愈合的初始阶段,嵌入物的机械稳定性至关重要,因为它消除了芯棒嵌入物的松动。它保证了被治疗的运动器械部件的特定几何形状将得以保留,并降低了治疗过程中发炎的风险。实验揭示了嵌入物的机械稳定性与增加的接触表面积有关的性质。结论我们观察到骨密度依赖性的非线性特性,它是描述骨的特性的主要参数,相对于以心轴相对于骨的滑动表面的形式表示的松动程度。在植入物愈合的初始阶段,嵌入物的机械稳定性至关重要,因为它消除了心轴嵌入物的松动。它保证了被治疗的运动器械部件的特定几何形状将得以保留,并降低了治疗过程中发炎的风险。结论我们观察到骨密度依赖性的非线性特性,它是描述骨的特性的主要参数,相对于以心轴相对于骨的滑动表面的形式表示的松动程度。在植入物愈合的初始阶段,嵌入物的机械稳定性至关重要,因为它消除了心轴嵌入物的松动。它保证了被治疗的运动器械部件的特定几何形状将得以保留,并降低了治疗过程中发炎的风险。结论我们观察到骨密度依赖性的非线性特性,它是描述骨的特性的主要参数,相对于以心轴相对于骨的滑动表面的形式表示的松动程度。在植入物愈合的初始阶段,嵌入物的机械稳定性至关重要,因为它消除了心轴嵌入物的松动。它保证了被治疗的运动器械部件的特定几何形状将得以保留,并降低了治疗过程中发炎的风险。在植入物愈合的初始阶段,嵌入物的机械稳定性至关重要,因为它消除了心轴嵌入物的松动。它保证了被治疗的运动器械部件的特定几何形状将得以保留,并降低了治疗过程中发炎的风险。在植入物愈合的初始阶段,嵌入物的机械稳定性至关重要,因为它消除了心轴嵌入物的松动。它保证了被治疗的运动器械部件的特定几何形状将得以保留,并降低了治疗过程中发炎的风险。
更新日期:2019-11-01
down
wechat
bug