Apparent Linear Attenuation Coefficients in Phase Contrast X-Ray Tomography.
Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms ( IF 1.4 ) Pub Date : 2011-08-15 , DOI: 10.1016/j.nimb.2011.05.018
Aimin Yan 1 , Xizeng Wu
Affiliation  

In the inline phase contrast x-ray tomography the reconstructed apparent linear attenuation coefficient values may be greatly larger than sample's linear attenuation coefficients or even be negative. In this work we present a general formula to quantitatively relate the apparent linear attenuation coefficient values in cone-beam phase contrast tomography to sample's linear attenuation coefficients and refractive indices. This formula overcomes the gross inaccuracy of the existing formula in the literature in analyzing high-resolution phase contrast tomography, and it will be useful for correctly interpreting and quantifying the apparent linear attenuation coefficients in cone-beam x-ray phase contrast tomography.