当前位置: X-MOL 学术Gastrointest. Endosc. › 论文详情
Our official English website, www.x-mol.net, welcomes your feedback! (Note: you will need to create a separate account there.)
Blue-light imaging compared with high-definition white light for real-time histology prediction of colorectal polyps less than 1 centimeter: a prospective randomized study
Gastrointestinal Endoscopy ( IF 6.7 ) Pub Date : 2018-09-28 , DOI: 10.1016/j.gie.2018.09.027
Emanuele Rondonotti , Silvia Paggi , Arnaldo Amato , Giuseppe Mogavero , Alida Andrealli , Francesco Simone Conforti , Dario Conte , Giancarlo Spinzi , Franco Radaelli

Background and Aims

Blue-light imaging (BLI) is a new chromoendoscopy technique, potentially useful for differentiating neoplastic from nonneoplastic lesions. The present study was aimed at comparing BLI with high-definition white light (HDWL) in the real-time histology prediction of colon polyps <10 mm.

Methods

Consecutive outpatients undergoing colonoscopy with the ELUXEO 7000 endoscopy platform and 760 series video colonoscopes (Fujifilm Co, Tokyo, Japan) who had at least 1 polyp <10 mm were randomized to BLI or HDWL for polyp characterization. The accuracy of high-confidence real-time histology prediction (adenoma vs not adenoma) by either BLI or HDWL for polyps <10 mm (primary end-point) and diminutive (≤5 mm) polyps was calculated, along with sensitivity, specificity, and positive and negative predictive values, with histopathology as the reference standard.

Results

A total of 483 polyps were detected in 245 randomized patients (125 and 120 in the BLI and HDWL arms, respectively). A total of 358 were diminutive, and 283 were adenomas. Overall, 222 (85.7%) and 193 (86.1%) polyps were characterized with high confidence by BLI and HDWL, respectively (P = .887), with an overall accuracy of 92% and 84%, respectively (P = .011). The accuracy was significantly higher by BLI than HDWL, also for diminutive polyps (92% vs 83%; P = .008). When BLI was used, the negative predictive value for diminutive rectosigmoid polyps was 88%, and the post-polypectomy surveillance interval was correctly attributed in 85.7% and 93.7% of patients, respectively, according to U.S. and European guidelines.

Conclusion

BLI was superior to HDWL for the real-time prediction of histology in polyps <10 mm. A BLI-dedicated classification might further improve the endoscopist performance. (Clinical trial registration number: NCT03274115.)