当前位置: X-MOL 学术Anal. Bioanal. Chem. › 论文详情
Our official English website, www.x-mol.net, welcomes your feedback! (Note: you will need to create a separate account there.)
In house validation of a high resolution mass spectrometry Orbitrap-based method for multiple allergen detection in a processed model food
Analytical and Bioanalytical Chemistry ( IF 3.8 ) Pub Date : 2018-02-13 00:00:00 , DOI: 10.1007/s00216-018-0927-8
Rosa Pilolli , Elisabetta De Angelis , Linda Monaci

In recent years, mass spectrometry (MS) has been establishing its role in the development of analytical methods for multiple allergen detection, but most analyses are being carried out on low-resolution mass spectrometers such as triple quadrupole or ion traps. In this investigation, performance provided by a high resolution (HR) hybrid quadrupole-Orbitrap™ MS platform for the multiple allergens detection in processed food matrix is presented. In particular, three different acquisition modes were compared: full-MS, targeted-selected ion monitoring with data-dependent fragmentation (t-SIM/dd2), and parallel reaction monitoring. In order to challenge the HR-MS platform, the sample preparation was kept as simple as possible, limited to a 30-min ultrasound-aided protein extraction followed by clean-up with disposable size exclusion cartridges. Selected peptide markers tracing for five allergenic ingredients namely skim milk, whole egg, soy flour, ground hazelnut, and ground peanut were monitored in home-made cookies chosen as model processed matrix. Timed t-SIM/dd2 was found the best choice as a good compromise between sensitivity and accuracy, accomplishing the detection of 17 peptides originating from the five allergens in the same run. The optimized method was validated in-house through the evaluation of matrix and processing effects, recoveries, and precision. The selected quantitative markers for each allergenic ingredient provided quantification of 60–100 μgingred/g allergenic ingredient/matrix in incurred cookies.

中文翻译:

内部验证的高分辨率质谱法基于Orbitrap的方法在加工的模型食品中进行多种过敏原检测

近年来,质谱(MS)在多种过敏原检测分析方法的开发中已经确立了自己的作用,但是大多数分析是在低分辨率质谱仪(例如三重四极杆或离子阱)上进行的。在这项调查中,展示了高分辨率(HR)混合四极杆-Orbitrap™MS平台为加工食品基质中的多种过敏原检测提供的性能。尤其是,比较了三种不同的采集模式:全质谱,具有数据依赖性碎片的目标选择离子监测(t-SIM / dd2)和平行反应监测。为了挑战HR-MS平台,样品制备应保持尽可能简单,仅限于30分钟的超声辅助蛋白质提取,然后用一次性尺寸排阻盒进行清理。在选择作为模型处理基质的自制饼干中,对追踪到的五种致敏成分(脱脂牛奶,全蛋,大豆粉,榛子和花生粉)的选定肽标记进行了监测。定时t-SIM / dd2被发现是最佳选择,因为它是灵敏度和准确性之间的良好折衷,在同一运行中完成了对来自五种过敏原的17种肽的检测。通过评估基质和加工效果,回收率和精密度,对优化方法进行了内部验证。为每种致敏成分选择的定量标记提供了60–100μg的定量在产生的饼干中加入/ g变应原性成分/基质。
更新日期:2018-02-13
down
wechat
bug