Test–Retest Reliability of the SERT Imaging Agent 11C-HOMADAM in Healthy Humans
The Journal of Nuclear Medicine ( IF 9.1 ) Pub Date : 2018-02-01 , DOI: 10.2967/jnumed.117.196915
Vikram Adhikarla , Boadie W. Dunlop , Nashwa Jarkas , Mark M. Goodman , Helen Mayberg , Michael J. Owens , Jonathon A. Nye

The aim of this study was to measure the test–retest reliability of 11C-N,N-dimethyl-2-(2′-amino-4′-hydroxymethylphenylthio)benzylamine (11C-HOMADAM) imaging of serotonin transporter (SERT) density in healthy control subjects. Methods: Two female and 2 male volunteers participated in the study, with each undergoing three 90-min 11C-HOMADAM PET scans. Time–activity curves were derived from SERT-rich structures and fit to 2 models: a simplified reference tissue model and a multilinear graphical model. Binding potential, the ratio of specifically bound uptake to nondisplaceable uptake at equilibrium, was calculated from the model parameter estimates. Ninety-five percent confidence intervals and the intraclass correlation coefficient (ICC) were calculated and adjusted for repeated measures. Results: The ICC values ranged from −0.13 in the dorsal raphe to 0.88 in the caudate nucleus. The highest average ICC values were in the striatum, but other regions were sensitive to measurement outliers. Conclusion: Good-to-excellent test–retest reliability was observed for SERT binding in the striatum. The dorsal raphe ICC value was sensitive to a measurement outlier. 11C-HOMADAM binding potential calculated from the simplified reference tissue model and the multilinear graphical model were robust and in good agreement.



中文翻译:

SERT成像剂11 C-HOMADAM在健康人类中的测试-再测试可靠性

本研究的目的是测量的重测信度11 C- N,N-二甲基-2-(2'-氨基-4'- hydroxymethylphenylthio)苄胺(11 C-HOMADAM)血清素转运蛋白(SERT)的成像健康对照对象中的密度。方法: 2名女性志愿者和2名男性志愿者参加了这项研究,每名志愿者进行了3次90分钟的11C-HOMADAM PET扫描。时间-活动曲线来自富含SERT的结构,并适合2种模型:简化的参考组织模型和多线性图形模型。从模型参数估计值计算结合电位,即平衡状态下特异性结合的摄取量与不可替代的摄取量之比。百分之九十五的置信区间和类内相关系数(ICC)被计算和调整以用于重复测量。结果: ICC值的范围从背缝的-0.13到尾状核的0.88。平均最高ICC值位于纹状体中,但其他区域对测量异常值敏感。结论:对于纹状体中的SERT结合,观察到了很好的再测信度。背缝ICC值对测量值异常敏感。从简化的参考组织模型和多线性图形模型计算得出的11 C-HOMADAM结合力很强并且吻合良好。

更新日期:2018-02-01
down
wechat
bug