Abstract
We have studied the electrochemical behaviour of room-temperature synthesized MOF-177. The MOF-177 sample was characterized by various techniques like Fourier transform infrared spectroscopy, scanning electron microscopy, energy dispersive X-ray, powder X-ray diffraction, nuclear magnetic resonance and CHNS elemental analysis. The MOF-177 electrode was prepared and electrochemical performance was carried out to explore the electrical activity of MOF-177. Cyclic voltammetry studies were performed in 0.05 M \(\hbox {K}_{4}\hbox {Fe(CN)}_{6}\) solution and electrochemical sensing experiments were performed in 0.05 M \(\hbox {H}_{2}\hbox {SO}_{4}\) and pH 7 buffer solution. A significantly increased electron transfer property has been observed and it has been explored for the electrochemical detection of heavy metal ions. The MOF-177 / cp electrode has shown excellent sensitivity towards toxic heavy metal ions such as \(\hbox {Pb}^{2+}\) and \(\hbox {Cd}^{2+}\) at the limit of detection of 0.004 and 0.03 \(\upmu \hbox {M}\), respectively.
Similar content being viewed by others
References
Tranchemontagne D J, Hunt J R and Omar Y M 2008 Tetrahedron 64 8553
Chae H K, Siberio-Pérez D Y, Kim J, Go Y B, Eddaoudi M, Matzger A J et al 2004 Nature 427 523
Saha D and Deng S 2010 J. Phys. Chem. Lett. 1 73
Li Y and Yang R T 2007 Langmuir 23 12937
Buica G-O, Ungureanu E M, Liviu B, Razus A C and Mandoc L-R 2013 J. Electroanal. Chem. 693 67
Goyer R A and Klaassen C D (ed) 1996 Progress in drug research25 958
Mouchrek V E M, Chierice G O and Marques A L B 1999 Quím Nova 22 312
Murray R W (ed) 1984 Elements of molecular and biomolecular electrochemistry (New York: Marcel Dekker) 3 191
Alizadeh S, Nematollahi D, Alizadeh S and Nematollahi D 2017 J. Am. Chem. Soc. 151 139
Abruña H D 1988 Coord. Chem. Rev. 86 135
Murray R W 1980 Acc. Chem. Res. 13 135
Utner W, Wang J, L’her M and Buck B P 1998 J. Pure Appl. Chem.70 1301
Arrigan D W (ed) 1994 Electroanalysis in biomedical and pharmaceutical sciences (USA: F. Scholz) 119 1953
Kalcher K 1990 Electroanalysis 2 419
Furukawa H, Miller M A and Yaghi M 2007 J. Mater. Chem. 17 3197
Jiao Y, Pei J, Yan C, Chen D, Hu Y and Chen G 2016 J. Mater. Chem. A 4 13344
Yuan B, Zhang J, Zhang R, Shi H, Guo X, Guo Y et al 2015 Int. J. Electrochem. Sci. 10 4899
Saha D and Deng S 2010 J. Phys. Chem. Lett.1 73
Müller M, Lebedevb O I and Fischer R A 2008 J. Mater. Chem. 18 5274
Ruslan N I, Lim D C K, Alang Ahmad S A, Abdul Aziz S F N, Supian F L and Yusof N A 2017 J. Electroanal. Chem. 799 497
Fan G, Zhai D and Zou D 2016 J. Electrochem. Sci. 11 4362
Mandil A and Pauliukaite R 2012 Anal. Lett. 45 395
El Mhammedi M A, Achak M, Najih R, Bakasse M and Chtaini A 2009 Mater. Chem. Phys. 115 567
Alizadeh T, Ganjali M R, Nourozi P, Zare M and Hoseini M 2017 Int. J. Electrochem. Sci. 12 5243
Nguyen P K Q and Lunsford S K 2013 JSM Chem. 1 1001
http://www.learnaboutelectronics.org/Resistors/resistors_01a.php
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Sangeetha, S., Krishnamurthy, G. Fabrication of MOF-177 for electrochemical detection of toxic \(\hbox {Pb}^{2+}\) and \(\hbox {Cd}^{2+}\) ions. Bull Mater Sci 43, 29 (2020). https://doi.org/10.1007/s12034-019-1979-x
Received:
Accepted:
Published:
DOI: https://doi.org/10.1007/s12034-019-1979-x