Abstract
Pultruded Glass Fiber-Reinforced Polymer (pultruded GFRP) composite produced by the pultrusion method has become popular in civil engineering applications due to its lightness, corrosion resistance and high strength. However, the use of the pultruded profile combining with reinforced concrete is still limited due to a lack of knowledge. Therefore, the behavior of the pultruded GFRP profile infilled with reinforced concrete beams (hybrid beams) is investigated. This study focused on the effects of stirrup spacing for the hybrid beams. Pursuant to this goal, a total of eight different beams were tested under four-point loading. One reference beam without the pultruded profile and seven hybrid beams having different stirrup spacings were considered. Moreover, the hybrid beams with and without stirrups were wrapped by unidirectional GFRP composite to investigate the effects of stirrup spacing on shear capacity of the beams strengthened by GFRP composite. The experimental findings revealed that tightening stirrups increased the load and energy dissipation capacities of the hybrid beams; however, it could not prevent brittle failure. On the other hand, wrapping hybrid beams with GFRP composite increased the load and energy dissipation capacities and also prevented brittle failure regardless of the presence of the stirrups. Therefore, it is strongly recommended that the unidirectional pultruded profiles should be strengthened with 90° GFRP wrapping to have ductile behavior.
Similar content being viewed by others
Data availability
The datasets generated during and/or analysed during the current study are available from the corresponding author on reasonable request.
References
Vedernikov A, Safonov A, Tucci F, Carlone P, Akhatov I. Pultruded materials and structures: a review. J Compos Mater. 2020;54:4081–117.
Korotkov R, Vedernikov A, Gusev S, Alajarmeh O, Akhatov I, Safonov A. Shape memory behavior of unidirectional pultruded laminate. Compos A Appl Sci Manuf. 2021;150: 106609.
Vedernikov A, Nasonov Y, Korotkov R, Gusev S, Akhatov I, Safonov A. Effects of additives on the cure kinetics of vinyl ester pultrusion resins. J Compos Mater. 2021;55:2921–37.
Vedernikov A, Safonov A, Tucci F, Carlone P, Akhatov I. Modeling spring-in of l-shaped structural profiles pultruded at different pulling speeds. Polymers. 2021;13:2748.
Özütok A, Madenci E. Free vibration analysis of cross-ply laminated composite beams by mixed finite element formulation. Int J Struct Stab Dyn. 2013;13:1250056.
Ozutok A, Madenci E, Kadioglu F. Free vibration analysis of angle-ply laminate composite beams by mixed finite element formulation using the Gâteaux differential. Sci Eng Compos Mater. 2014;21:257–66.
Aribas UN, Ermis M, Eratli N, Omurtag MH. The static and dynamic analyses of warping included composite exact conical helix by mixed FEM. Compos B Eng. 2019;160:285–97.
Aksoylu C. Experimental analysis of shear deficient reinforced concrete beams strengthened by glass fiber strip composites and mechanical stitches. Steel Composite Struct Int J. 2021;40:267–85.
Vedernikov A, Gemi L, Madenci E, Özkılıç YO, Yazman Ş, Gusev S, et al. Effects of high pulling speeds on mechanical properties and morphology of pultruded GFRP composite flat laminates. Compos Struct. 2022;301: 116216.
Gemi L, Madenci E, Özkılıç YO, Yazman Ş, Safonov A. Effect of fiber wrapping on bending behavior of reinforced concrete filled pultruded GFRP composite hybrid beams. Polymers. 2022;14:3740.
Madenci E, Özkılıç YO, Gemi L. Experimental and theoretical investigation on flexure performance of pultruded GFRP composite beams with damage analyses. Compos Struct. 2020;242: 112162.
Aksoylu C. Shear strengthening of reinforced concrete beams with minimum CFRP and GFRP strips using different wrapping technics without anchoring application. Steel Composite Struct Int J. 2022;44:845–965.
Aksoylu C, Özkılıç YO, Madenci E, Safonov A. Compressive behavior of pultruded GFRP boxes with concentric openings strengthened by different composite wrappings. Polymers. 2022;14:4095.
Madenci E, Özkılıç YO, Aksoylu C, Safonov A. The effects of eccentric web openings on the compressive performance of pultruded GFRP boxes wrapped with GFRP and CFRP sheets. Polymers. 2022;14:4567.
Madenci E, Özkılıç YO, Gemi L. Buckling and free vibration analyses of pultruded GFRP laminated composites: experimental, numerical and analytical investigations. Compos Struct. 2020;254: 112806.
Nunes F, Correia JR, Silvestre N. Structural behaviour of hybrid FRP pultruded columns. Part 1: experimental study. Composite Struct. 2016;139:291–303.
Lokuge W, Abousnina R, Herath N. Behaviour of geopolymer concrete-filled pultruded GFRP short columns. J Compos Mater. 2019;53:2555–67.
Gemi L, Madenci E, Özkılıç YO. Experimental, analytical and numerical investigation of pultruded GFRP composite beams infilled with hybrid FRP reinforced concrete. Eng Struct. 2021;244: 112790.
Koaik A, Bel S, Jurkiewiez B. Experimental tests and analytical model of concrete-GFRP hybrid beams under flexure. Compos Struct. 2017;180:192–210.
Yin P, Huang L, Yan L, Zhu D. Compressive behavior of concrete confined by CFRP and transverse spiral reinforcement. Part A: experimental study. Mater Struct. 2016;49:1001–11.
Saribiyik A, Abodan B, Balci MT. Experimental study on shear strengthening of RC beams with basalt FRP strips using different wrapping methods. Eng Sci Technol Int J. 2021;24:192–204.
Gemi L, Aksoylu C, Yazman Ş, Özkılıç YO, Arslan MH. Experimental investigation of shear capacity and damage analysis of thinned end prefabricated concrete purlins strengthened by CFRP composite. Compos Struct. 2019;229: 111399.
Aksoylu C, Özkılıç YO, Arslan MH. Damages on prefabricated concrete dapped-end purlins due to snow loads and a novel reinforcement detail. Eng Struct. 2020;225: 111225.
Aksoylu C, Özkılıç YO, Yazman Ş, Gemi L, Arslan MH. Experimental and numerical investigation of load bearing capacity of thinned end precast purlin beams and solution proposals. Teknik Dergi. 2021;32(3):10823.
Boscato G, Ientile S. Experimental and numerical investigation on dynamic properties of thin-walled GFRP buckled columns. Compos Struct. 2018;189:273–85.
Xin H, Mosallam A, Liu Y, Xiao Y, He J, Wang C, et al. Experimental and numerical investigation on in-plane compression and shear performance of a pultruded GFRP composite bridge deck. Compos Struct. 2017;180:914–32.
Zou X, Feng P, Wang J, Wu Y, Feng Y. FRP stay-in-place form and shear key connection for FRP-concrete hybrid beams/decks. Compos Struct. 2018;192:489–99.
Minghini F, Tullini N, Laudiero F. Identification of the short-term full-section moduli of pultruded FRP profiles using bending tests. J Compos Constr. 2014;18:1–9.
Zhang P, Liu X-Y, Li Q-L, Deng E-F, Gao D-Y, Zhang Z, et al. Experimental and theoretical studies on the shear performance of innovative box-shape FRP profile-concrete hybrid beams. Structures. 2020;28:2772–84.
Muttashar M, Karunasena W, Manalo A, Lokuge W. Behaviour of hollow pultruded GFRP square beams with different shear span-to-depth ratios. J Compos Mater. 2016;50:2925–40.
Ribeiro M, Tavares C, Ferreira AJ, Marques AT. Static flexural performance of GFRP-polymer concrete hybrid beams. Key Eng Mater. 2002;230:148–51.
Correia J, Branco F, Ferreira J. Structural Behaviour of GFRP-Concrete hybrid beams. Composites in Construction–Third International Conference, Lyon, France2005.
Hulatt J, Hollaway L, Thorne A. The use of advanced polymer composites to form an economic structural unit. Constr Build Mater. 2003;17:55–68.
Hulatt J, Hollaway L, Thorne A. Short term testing of hybrid T beam made of new prepreg material. J Compos Constr. 2003;7:135–44.
Bloodworth A, Szczerbicki J. Advanced polymer composite and concrete beam and slab systems. Advanced polymer composites for structural applications in construction: Elsevier; 2004. p. 327-34.
Garden H. The use of advanced composite materials in long span civil engineering infrastructure. Advanced polymer composites for structural applications in construction: Elsevier; 2004. p. 343–52.
Li T, Feng P, Ye L. Experimental study on FRP-concrete hybrid beams. Third international conference on FRP composites in civil engineering Miami, Florida: International Institute for FRP in Construction: Citeseer; 2006. p. 343–6.
Hanus JP, Bank LC, Oliva MG. Combined loading of a bridge deck reinforced with a structural FRP stay-in-place form. Constr Build Mater. 2009;23:1605–19.
Kim YJ, Fam A. Numerical analysis of pultruded GFRP box girders supporting adhesively-bonded concrete deck in flexure. Eng Struct. 2011;33:3527–36.
Honickman HN, Fam A. Pultruded GFRP sections as stay-in-place structural open formwork for concrete slabs and girders. Queen's University, Msc Thesis; 2008.
Neagoe CA. Structural performance of FRP-concrete hybrid beams with flexible shear connection, Universitat Politècnica de Catalunya, PhD Thesis; 2016.
Standard T. TS500: restrictions for design and construction of R/C structures. Ankara: The Minister of Public Works and Settlement; 2000.
ACI-318. Building code requirements for structural concrete (ACI 318-05) and commentary (ACI 318R-05). American Concrete Institute; 2005.
2 E. Design of concrete structures Part 1–1: General rules and rules for buildings2004.
Özkılıç YO, Aksoylu C, Arslan MH. Numerical evaluation of effects of shear span, stirrup spacing and angle of stirrup on reinforced concrete beam behaviour. Struct Eng Mech Int J. 2021;79:309–26.
Acknowledgements
This study has been supported by the Department of Scientific Research Projects at Necmettin Erbakan University with the project coded 201219004. The opinions expressed in this paper are those of the authors and do not reflect the views of the sponsor.
Funding
Funding was received for this work. All of the sources of funding for the work described in this publication are acknowledged below: Department of Scientific Research Projects at Necmettin Erbakan University with the project coded 201219004.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
The authors confirm that there are no known conflicts of interest associated with this publication and there has been no financial support for this work that could have influenced its outcome.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.
About this article
Cite this article
Özkılıç, Y.O., Gemi, L., Madenci, E. et al. Effects of stirrup spacing on shear performance of hybrid composite beams produced by pultruded GFRP profile infilled with reinforced concrete. Archiv.Civ.Mech.Eng 23, 36 (2023). https://doi.org/10.1007/s43452-022-00576-5
Received:
Revised:
Accepted:
Published:
DOI: https://doi.org/10.1007/s43452-022-00576-5