Referencing for anterior atlantoaxial trans-articular osteosynthesis: a radiological study and proposal of a decisional algorithm

  • Original Article
  • Published:
European Spine Journal Aims and scope Submit manuscript

Abstract

Purpose

Anterior trans-articular C1–C2 screw placement can be considered as a surgical alternative in different conditions affecting the atlantoaxial region. While its rigidity is similar to posterior Magerl and Harms techniques, it also provides some surgical advantages. However, the literature lacks papers exhaustively describing indication criteria, surgical steps, and pitfalls.

Methods

This is a radiological study on 100 healthy subjects. Thin-layer CT scans of the craniovertebral junction were retrieved from the institutional database. The coronal inclination of the C1–C2 joint rim and the depth of the entry point of the screw with respect to the anterior profile of C2 were measured. The antero-posterior and the medio-lateral surgical corridors for the screw placement, and the wideness of the target area on the upper surface of C1 were also measured.

Results

The multivariate analysis showed that the coronal inclination of the C1–C2 articular joint rim strongly influences the surface extension of the C1 target area; the depth of the entry point and the C1–C2 articular rim inclination seem to be independent factors in influencing both the medio-lateral and the antero-posterior surgical corridors wideness. A decisional algorithm on whether to perform an anterior or posterior approach to the atlantoaxial region was also proposed.

Conclusions

We can conclude that, as much as the C1–C2 articular rim is tending to the horizontal line, and as deeper is the entry point of the screw on the anterior profile of C2, as easier the anterior C1–C2 trans-articular screw placement will result.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5.

Similar content being viewed by others

References

  1. La Rocca G, Altieri R, Ricciardi L et al (2017) Anatomical study of occipital triangles: the “inferior” suboccipital triangle, a useful vertebral artery landmark for safe postero-lateral skull base surgery. Acta Neurochir (Wien) 159(10):1887–1891

    Article  Google Scholar 

  2. Ricciardi L, Trungu S, Scerrati A et al (2020) Odontoid screw placement for Anderson type II odontoid fractures: how do duration from injury to surgery and clinical and radiological factors influence the union rate? A multicenter retrospective study. J Neurosurg Spine 2:1–5

    Google Scholar 

  3. Du JY, Aichmair A, Kueper J et al (2015) Biomechanical analysis of screw constructs for atlantoaxial fixation in cadavers: a systematic review and meta-analysis. J Neurosurg Spine 22(2):151–161

    Article  Google Scholar 

  4. Lu B, He X, Zhao C et al (2009) Biomechanical study of artificial atlanto-odontoid joint. Spine Phila Pa 1976) 34(18):1893–1899

    Article  Google Scholar 

  5. Lofrese G, Cultrera F, Visani J et al (2019) Intraoperative Doppler ultrasound as a means of preventing vertebral artery injury during Goel and Harms C1–C2 posterior arthrodesis: technical note. J Neurosurg Spine. https://doi.org/10.3171/2019.5.SPINE1959

    Article  Google Scholar 

  6. Gautschi OP, Payer M, Corniola MV et al (2014) Clinically relevant complications related to posterior atlanto-axial fixation in atlanto-axial instability and their management. Clin Neurol Neurosurg 123:131–135

    Article  CAS  Google Scholar 

  7. Akinduro OO, Baum GR, Howard BM et al (2016) Neurological outcomes following iatrogenic vascular injury during posterior atlanto-axial instrumentation. Clin Neurol Neurosurg 150:110–116

    Article  Google Scholar 

  8. De Bonis P, Iaccarino C, Musio A et al (2019) Functional outcome of elderly patients treated for odontoid fracture: a multicenter study. Spine (Phila Pa 1976) 44(13):951–958

    Article  Google Scholar 

  9. Polli FM, Miscusi M, Forcato S et al (2015) Atlantoaxial anterior transarticular screw fixation: a case series and reappraisal of the technique. Spine J 15(1):185–193

    Article  Google Scholar 

  10. Reindl R, Sen M, Aebi M (2003) Anterior instrumentation for traumatic C1–C2 instability. Spine 28(17):E329

    Article  Google Scholar 

  11. Sen MK, Steffen T, Beckman L et al (2005) Atlantoaxial fusion using anterior transarticular screw fixation of C1–C2: technical innovation and biomechanical study. Eur Spine J 14(5):512–518

    Article  Google Scholar 

  12. Ricciardi L, Sturiale CL, Izzo A et al (2019) Submandibular approach for single-stage craniovertebral junction ventral decompression and stabilization: a preliminary cadaveric study of technical feasibility. World Neurosurg 127:206–212

    Article  Google Scholar 

  13. Lu J, Ebraheim NA, Yang H et al (1998) Anatomic considerations of anterior transarticular screw fixation for atlantoaxial instability. Spine 23(11):1229–1235

    Article  CAS  Google Scholar 

  14. Ricciardi L, Montano N, D’Onofrio GF et al (2020) X-ray exposure in odontoid screwing for Anderson type II fracture: comparison between O-arm and C-arm-assisted procedures. Acta Neurochir (Wien) 162(3):713–718

    Article  Google Scholar 

  15. Kirnaz S, Gebhard H, Wong T et al (2021) Intraoperative image guidance for cervical spine surgery. Ann Transl Med 9(1):93

    Article  Google Scholar 

  16. Pisapia JM, Nayak NR, Salinas RD et al (2017) Navigated odontoid screw placement using the O-arm: technical note and case series. J Neurosurg Spine 26(1):10–18

    Article  Google Scholar 

  17. Lapsiwala SB, Anderson PA, Oza A et al (2006) Biomechanical comparison of four C1 to C2 rigid fixative techniques: anterior transarticular, posterior transarticular, C1 to C2 pedicle, and C1 to C2 intralaminar screws. Neurosurgery 58(3):516–521

    Article  Google Scholar 

  18. Grob D, Magerl F (1987) Surgical stabilization of C1 and C2 fractures. Orthopade 16(1):46–54

    CAS  Google Scholar 

  19. Harms J, Melcher RP (2001) Posterior C1–C2 fusion with polyaxial screw and rod fixation. Spine (Phila Pa 1976) 26(22):2467–2471

    Article  CAS  Google Scholar 

  20. Panjabi M, Dvorak J, Duranceau J et al (1988) Three-dimensional movements of the upper cervical spine. Spine (Phila Pa 1976) 13(7):726–730

    Article  CAS  Google Scholar 

  21. Tessitore E, Bartoli A, Schaller K et al (2011) Accuracy of freehand fluoroscopy-guided placement of C1 lateral mass and C2 isthmic screws in atlanto-axial instability. Acta Neurochir (Wien) 153(7):1417–1425; discussion 1425

    Article  Google Scholar 

  22. Gradl G, Maier-Bosse T, Penning R et al (2005) Quantification of C2 cervical spine rotatory fixation by X-ray. MRI and CT Eur Radiol 15(2):376–382

    Article  Google Scholar 

  23. Pang D, Nemzek WR, Zovickian J (2007) Atlanto-occipital dislocation–part 2: The clinical use of (occipital) condyle-C1 interval, comparison with other diagnostic methods, and the manifestation, management, and outcome of atlanto-occipital dislocation in children. Neurosurgery 61(5):995–1015; discussion 1015

    Article  Google Scholar 

  24. Ji W, Zheng M, Tong J et al (2015) Feasibility and trajectory study of anterior transarticular crossing screw placement for atlantoaxial joint instability: a cadaveric study and description of a novel technique. Eur Spine J 24(12):2954–2960

    Article  Google Scholar 

  25. Koller H, Kammermeier V, Ulbricht D et al (2006) Anterior retropharyngeal fixation C1–2 for stabilization of atlantoaxial instabilities: study of feasibility, technical description and preliminary results. Eur Spine J 15(9):1326–1338

    Article  Google Scholar 

Download references

Funding

This research received no external funding.

Author information

Authors and Affiliations

Authors

Contributions

MM contributed to conceptualization, methodology, writing—original draft preparation, writing—reviewing and editing. LR contributed to conceptualization, writing—reviewing and editing, formal analysis, data curation. AP contributed to data curation, writing—original draft preparation. MC contributed to investigation, visualization. GL contributed to software, investigation, visualization. MA contributed to formal analysis, data curation. ST contributed to validation, supervision. AR contributed to writing—reviewing and editing, supervision.

Corresponding author

Correspondence to Sokol Trungu.

Ethics declarations

Conflict of interest

The authors report no conflict of interest concerning the materials or methods used in this study or the findings specified in this paper.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Supplementary Information

Below is the link to the electronic supplementary material.

3D printable model of the atlantoaxial complex, entry points, and the working corridors for screws placement (MP4 8174 kb).

Rights and permissions

Springer Nature or its licensor holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Miscusi, M., Ricciardi, L., Piazza, A. et al. Referencing for anterior atlantoaxial trans-articular osteosynthesis: a radiological study and proposal of a decisional algorithm. Eur Spine J 31, 3410–3417 (2022). https://doi.org/10.1007/s00586-022-07380-y

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00586-022-07380-y

Keywords

Navigation