Synovium removal from the articular side of the quadriceps tendon around the superior pole of patella reduces the crepitus after total knee arthroplasty

  • Original Paper
  • Published:
International Orthopaedics Aims and scope Submit manuscript

Abstract

Purpose

The purpose of this study was to investigate whether synovium removal from the articular side of the quadriceps tendon around the superior pole of the patella after total knee arthroplasty (TKA) reduced the incidence of patellar crepitus (PC) or not.

Methods

We retrospectively reviewed 134 consecutive patients who underwent primary posterior stabilized (PS)-TKA by one surgeon from 2010 to 2013. Sixty-seven patients performed without touching synovium at superior pole of patella and 67 patients performed with removing all synovium from superior pole of patella were compared; none had patellar resurfacing. Patients were followed up two and six weeks, three, six and 12 months and annually thereafter. The primary outcome was the incidence of PC, detected during follow-up, and was graded as absent (0), fine (1), or coarse (2).

Results

At one year of follow-up, the synovial removal (SR) group had a significant lower rate of PC compared to the synovial preserved (SP) group: 15/67 (22%) vs 34/67 (51%), adjusted odds ratio = 0.29, 95% confidence interval (CI) = 0.14 to 0.64, P = 0.002. All PC in SR group were grade 1 while four knees in SP group were grade 2. Mean PC onset was eight months after surgery (range 1.5 to 12, P = 0.78) in both groups.

Conclusion

Removal of the synovium from the articular side of the quadriceps tendon around the superior pole of patellar reduced the incidence of PC after primary PS-TKA without patellar resurfacing. This is a promising technique and might enlighten surgeons to reduce the noise and improve patient satisfaction after total knee replacement.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4

Similar content being viewed by others

References

  1. Hwang BH, Nam CH, Jung KA, Ong A, Lee SC (2013) Is further treatment necessary for patellar crepitus after total knee arthroplasty? Clin Orthop Relat Res 471(2):606–612

    Article  Google Scholar 

  2. Dennis DA, Kim RH, Johnson DR, Springer BD, Fehring TK, Sharma A (2011) The John Insall award: control-matched evaluation of painful patellar crepitus after total knee arthroplasty. Clin Orthop Relat Res 469(1):10–17

    Article  Google Scholar 

  3. Aglietti P, Buzzi R, Gaudenzi A (1988) Patellofemoral functional results and complications with the posterior stabilized total condylar knee prosthesis. J Arthroplasty 3(1):17–25

    Article  CAS  Google Scholar 

  4. Frye BM, Floyd MW, Pham DC, Feldman JJ, Hamlin BR (2012) Effect of femoral component design on patellofemoral crepitance and patella clunk syndrome after posterior-stabilized total knee arthroplasty. J Arthroplasty 27(6):1166–1170

    Article  Google Scholar 

  5. Choi WC, Ryu KJ, Lee S, Seong SC, Lee MC (2013) Painful patellar clunk or crepitation of contemporary knee prostheses. Clin Orthop Relat Res 471(5):1512–1522

    Article  Google Scholar 

  6. Huang YF, Gao YH, Ding L, Liu B, Liu JG, Qi X (2020) Influence of femoral implant design modification on anterior knee pain and patellar crepitus in patients who underwent total knee arthroplasty without patella resurfacing. BMC Musculoskelet Disord 21(1):364

    Article  Google Scholar 

  7. Ranawat CS, White PB, West S, Ranawat AS (2017) Clinical and radiographic results of Attune and PFC Sigma knee designs at 2-year follow-up: a prospective matched-pair analysis. J Arthroplasty 32(2):431–436

    Article  Google Scholar 

  8. Lonner JH, Jasko JG, Bezwada HP, Nazarian DG, Booth RE Jr (2007) Incidence of patellar clunk with a modern posterior-stabilized knee design. Am J Orthop (Belle Mead NJ) 36(10):550–553

    Google Scholar 

  9. Ranawat AS, Ranawat CS, Slamin JE, Dennis DA (2006) Patellar crepitation in the P.F.C. sigma total knee system. Orthopedics. 29(9 Suppl):S68-70

    PubMed  Google Scholar 

  10. Schroer WC, Diesfeld PJ, Reedy ME, LeMarr A (2009) Association of increased knee flexion and patella clunk syndrome after mini-subvastus total knee arthroplasty. J Arthroplasty 24(2):281–287

    Article  Google Scholar 

  11. Fukunaga K, Kobayashi A, Minoda Y, Iwaki H, Hashimoto Y, Takaoka K (2009) The incidence of the patellar clunk syndrome in a recently designed mobile-bearing posteriorly stabilised total knee replacement. J Bone Joint Surg Br 91(4):463–468

    Article  CAS  Google Scholar 

  12. Martin JR, Jennings JM, Watters TS, Levy DL, McNabb DC, Dennis DA (2017) Femoral implant design modification decreases the incidence of patellar crepitus in total knee arthroplasty. J Arthroplasty 32(4):1310–1313

    Article  Google Scholar 

  13. Peralta-Molero JV, Gladnick BP, Lee YY, Ferrer AV, Lyman S, González Della Valle A (2014) Patellofemoral crepitation and clunk following modern, fixed-bearing total knee arthroplasty. J Arthroplasty 29(3):535–40

    Article  Google Scholar 

  14. Thiengwittayaporn S, Srungboonmee K, Chiamtrakool B (2019) Resurfacing in a posterior-stabilized total knee arthroplasty reduces patellar crepitus complication: a randomized, controlled trial. J Arthroplasty 34(9):1969–1974

    Article  Google Scholar 

  15. Thiengwittayaporn S, Sumranwanich N, Hongku N, Sansawat P (2021) Onlay patellar resurfacing in a posterior-stabilized total knee arthroplasty increases patellar crepitus complication: a randomized, controlled trial. J Arthroplasty 36(10):3443–3450

    Article  Google Scholar 

  16. Duan G, Cai S, Lin W, Pan Y (2021) Risk factors for patellar clunk or crepitation after primary total knee arthroplasty: a systematic review and meta-analysis. J Knee Surg 34(10):1098–1109

    Article  Google Scholar 

Download references

Acknowledgements

We thank Bob Taylor, PhD, for reviewing the article and language help. We also thank all participants for providing the data used in this study.

Author information

Authors and Affiliations

Authors

Contributions

All authors contributed to the study conception and design. Material preparation, data collection, and analysis were performed by Sukanis Chumchuen, Supakit Kanitnate, Kittipong Wattanasirisombat, and Nattapol Tammachote. The first draft of the manuscript was written by Sukanis Chumchuen and all authors commented on previous versions of the manuscript. All authors read and approved the final manuscript.

Corresponding author

Correspondence to Sukanis Chumchuen.

Ethics declarations

Ethics approval

This study was performed in line with the principles of the Declaration of Helsinki. Approval was granted by the Ethics Committee of Thammasat University (MTU-EC-OT-0-100/56) prior to any review process.

Conflict of interest

The authors declare no competing interests.

Additional information

Publisher's note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Springer Nature or its licensor holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Chumchuen, S., Kanitnate, S., Wattanasirisombat, K. et al. Synovium removal from the articular side of the quadriceps tendon around the superior pole of patella reduces the crepitus after total knee arthroplasty. International Orthopaedics (SICOT) 46, 2561–2567 (2022). https://doi.org/10.1007/s00264-022-05539-2

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00264-022-05539-2

Keywords

Navigation