Influence of Measurement Parameters on the Accuracy of Determining the Capacity of a Vertical Tank

  • INNOVATIVE TECHNOLOGIES OF OIL AND GAS
  • Published:
Chemistry and Technology of Fuels and Oils Aims and scope

Vertical tanks are commonly used for oil storage. The accuracy of measurement of the tank’s capacity depends directly on the method used for processing the experimental data. When the Monte Carlo method is applied for evaluating the capacity of a vertical tank, the measurement result is determined by the factors of sensor point distribution, sensor point density, and sample point density. Therefore, in this study, we investigate the impact of these factors and their influence on the evaluated capacity of a vertical tank based on the Monte Carlo method. The research results show that the absolute and relative errors of the orderly distribution are similar to those of the rotary distribution, their absolute errors do not exceed ± 0.1 m3, and the relative errors can be converged to within 0.1%. When the sensor points are randomly distributed, the stable value of the absolute error differs from 0, and the relative error cannot be converged to within 0.1%, thus, the random distribution is not acceptable for measuring the capacity of vertical tanks. When the sensor point density is higher than or equal to 1.44 /m2, the absolute error of the measurement result does not exceed ± 0.1 m3, and the relative error can be converged to within 0.1%, which is acceptable for measuring the capacity of vertical tanks. The higher the sample point density, the smaller the absolute error range and the faster the relative error convergence speed. When the sample point density is higher than or equal to 1745.23 /m3, the relative error can be converged to within 0.1%.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1.
Fig. 2.
Fig. 3.
Fig. 4.
Fig. 5.
Fig. 6.
Fig. 7.
Fig. 8.

Similar content being viewed by others

References

  1. JJG 168-2005, “Verification regulation for vertical metal tank capacity,” State Administration for Market Regulation, China.

  2. ISO 7507-1-2003, “Petroleum and liquid petroleum products - Calibration of vertical cylindrical tanks - Part 1: Strapping method,” International Organisation for Standardization.

  3. H.D. Hao, X.L. Chen, H.L. Shi, X.M. Liang, and P.J. Yi, “The automatic measurement system of large vertical storage tank volume based on 3D laser scanning principle,” 13th IEEE International Conference on Electronic Measurement & Instruments (ICEMI), pp. 211-216 (2017).

  4. V. Knyva, M. Knyva, and J. Rainys, “New approach to calibration of vertical fuel tanks,” Elektron. Elektrotech., 19(8), 37-40 (2013).

    Article  Google Scholar 

  5. ISO 12917-1:2002, “Calibration of horizontal cylindrical tanks - Part 1: Manual methods,” International Organisation for Standardization.

  6. J.T. Wang, Z.Y. Liu, L. Tong, L. Zhang, L.G. Guo, and X.S. Bao, “The non-contact precision measurement and noise reduction method for liquid volume metrology,” Proc. SPIE, 8321, id832133 (2011).

  7. G. Y. Chen, Y. Wan, H. H. Lin, H. L. Hu, G. X. Liu, and Y. H. Peng. “Vertical tank capacity measurement based on Monte Carlo method,” PLoS One, 16(4), e0250207 (2021).

    Article  CAS  Google Scholar 

Download references

This work was supported by the Natural Science Foundation of Guangdong Province (No.2020A1515010947), the Scientific and Technological Planning Project of Guangzhou City (No.202002030439), the Technology Project of Guangzhou Administration for Market Regulation (No.2020kj33), and the Natural Science Foundation of Guangxi Province (No.2018GXNSFBA281184).

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Guoyu Chen.

Additional information

Translated from Khimiya i Tekhnologiya Topliv i Masel, No. 1, pp. 132–139 January – February, 2022.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Chen, G., Xiao, T., Yan, Y. et al. Influence of Measurement Parameters on the Accuracy of Determining the Capacity of a Vertical Tank. Chem Technol Fuels Oils 58, 122–130 (2022). https://doi.org/10.1007/s10553-022-01359-7

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10553-022-01359-7

Keywords

Navigation