Skip to main content

Value of variation of end-tidal carbon dioxide for predicting fluid responsiveness during the passive leg raising test in patients with mechanical ventilation: a systematic review and meta-analysis

Abstract

Background

The ability of end-tidal carbon dioxide (ΔEtCO2) for predicting fluid responsiveness has been extensively studied with conflicting results. This meta-analysis aimed to explore the value of ΔEtCO2 for predicting fluid responsiveness during the passive leg raising (PLR) test in patients with mechanical ventilation.

Methods

PubMed, Embase, and Cochrane Central Register of Controlled Trials were searched up to November 2021. The diagnostic odds ratio (DOR), sensitivity, and specificity were calculated. The summary receiver operating characteristic curve was estimated, and the area under the curve (AUROC) was calculated. Q test and I2 statistics were used for study heterogeneity and publication bias was assessed by Deeks’ funnel plot asymmetry test. We performed meta-regression analysis for heterogeneity exploration and sensitivity analysis for the publication bias.

Results

Overall, six studies including 298 patients were included in this review, of whom 149 (50%) were fluid responsive. The cutoff values of ΔEtCO2 in four studies was 5%, one was 5.8% and the other one was an absolute increase 2 mmHg. Heterogeneity between studies was assessed with an overall Q = 4.098, I2 = 51%, and P = 0.064. The pooled sensitivity and specificity for the overall population were 0.79 (95% CI 0.72–0.85) and 0.90 (95% CI 0.77–0.96), respectively. The DOR was 35 (95% CI 12–107). The pooled AUROC was 0.81 (95% CI 0.77–0.84). On meta-regression analysis, the number of patients was sources of heterogeneity. The sensitivity analysis showed that the pooled DOR ranged from 21 to 140 and the pooled AUC ranged from 0.92 to 0.96 when one study was omitted.

Conclusions

Though the limited number of studies included and study heterogeneity, our meta-analysis confirmed that the ΔEtCO2 performed moderately in predicting fluid responsiveness during the PLR test in patients with mechanical ventilation.

Introduction

Fluid resuscitation is recommended and widely used as the first-line resuscitative therapy for all patients presenting with acute circulatory failure [1]. Although the volume status of a shocked patient is recovered, evidence suggests that inappropriate administration of fluids has deleterious effects such as volume overload, systemic and pulmonary edema, and limitation of oxygen diffusion to tissues, thereby leading to increased tissue hypoxia [2,3,4]. Therefore, it is important to obtain reliable information about fluid responsiveness in patients having a circulatory failure in the intensive care unit. However, clinicians are often faced with inaccurate, nonspecific information to guide their treatment.

Previous studies have shown that some parameters may be related to volume status. The traditional static parameters, such as intrathoracic blood volume index, pulmonary wedge pressure, and central venous pressure, have been proved not related to patient volume status [5, 6]. Hemodynamic parameters, such as pulse pressure variation and stroke volume variation, may better predict fluid responsiveness. However, the evaluation of these parameters requires invasive procedures and special monitoring equipment, limiting their clinical application [7].

Passive leg raising (PLR) induces a rapid and reversible increase in preload through an increase in venous return mimicking fluid administration. This maneuver has been demonstrated to predict fluid responsiveness [8, 9], However, a fast response and direct measurement technique of the effect on cardiac output is needed. Nevertheless, the need to monitor cardiac output with echocardiography, arterial pulse contour analysis, bioreactance, or esophageal Doppler is unachievable or inconvenient under many clinical conditions.

End-tidal carbon dioxide (EtCO2) is the partial pressure of carbon dioxide (PCO2) in the exhaled air measured at the end of expiration. Measurement of EtCO2 using capnography provides a noninvasive estimate of cardiac output during cardiac arrest and can therefore be used to monitor the quality of cardiopulmonary resuscitation and predict return of spontaneous circulation [10,11,12].In recent years, the variation of EtCO2 (ΔEtCO2) during passive leg raising (PLR) test or fluid challenge has been considered as a tool to help guide fluid resuscitation [13,14,15,16,17,18,19], however, the results conflicting. Physiologically, EtCO2 depends on three variables: tissue CO2 production, pulmonary blood flow (i.e., cardiac output), and alveolar ventilation [20]. Thus, EtCO2 may accurately reflect cardiac output when ventilator parameters and CO2 production are constant. This correlation has been tested in experimental [21] and clinical [22] studies. Since PLR is a short maneuver, these two factors are assumed to be constant and therefore, EtCO2 should mainly reflect changes in CO, it is theoretically possible to assess fluid responsiveness after PLR test.

In this systematic review and meta-analysis, the test characteristics of ΔEtCO2 were summarized as a predictor of fluid responsiveness during PLR test in patients with mechanical ventilation to elucidate their diagnostic performance further and provide information for the detection of fluid responders.

Materials and methods

This meta-analysis was conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-analyses guidance [23].

Registration and protocol

This meta-analysis was registered on PROSPERO (CRD42021284241).

Search strategy

Relevant studies up to November 2021 were searched in the PubMed, Embase, and Cochrane Library databases with the following terms and their combinations: “fluid therapy OR fluid responsive OR volume responsive,” “end tidal carbon dioxide OR end-tidal carbon dioxide OR EtCO2” and “mechanical ventilation OR ventilated.” All scanned abstracts, studies, and citations were reviewed. Moreover, references of the retrieved manuscripts were also manually cross-searched for further relevant publications.

Selection criteria

The inclusion criteria were as follows: (1) studies on patients receiving mechanical ventilation; (2) studies with PLR-induced increase in EtCO2 as the index test; (3) studies with a CO monitoring for the diagnosis of fluid responsiveness; (4) studies published with full-text in any language; (5) studies providing sufficient data for constructing 2-by-2 tables, including true positive (TP), false positive (FP), true negative (TN), and false negative (FN). The exclusion criteria were as follows: (1) studies that used the same population or overlapping database and (2) studies on animal models.

Data extraction and quality assessment

All the available data were extracted from each study by two investigators independently according to the aforementioned inclusion criteria, and any differences were resolved by discussion with a third investigator. The following data were collected from each study: (1) basic characteristics of studies, including first author name, publication year, country where the research was performed, selected patients, gender, mean age, number of patients, tidal volume, index test device for the EtCO2, reference standard measurement for cardiac output monitoring, reference standard threshold, and reference standard device; (2) diagnostic performance, including cutoff value, sensitivity, specificity, area under the receiver operator characteristic curve (AUROC), TP, FP, FN, and TN. The quality of included studies was scored independently by two reviewers using the revised Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) criteria [24]. The quality of studies was assessed using RevMan 5.4.

Statistical analysis

All analyses were performed using the Stata 16.0 software (Stata Corp., College Station, TX, USA). The bivariate meta-analysis model was employed to summarize sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio (DOR) [25, 26]. The sensitivity and specificity of each included study were used to plot the summary receiver operator characteristic (SROC) curve and calculate the area under the SROC curve (AUC). Diagnostic power was good, moderate, and poor if the AUC was more than 0.8, between 0.7 and 0.8, and less than 0.7, respectively [27]. As publication bias is a concern for meta-analyses, the Deeks’ funnel plot asymmetry test was used, with P < 0.10 indicating statistical significance [28]. If publication bias was present, a sensitivity analysis of DOR was performed to explore why.

Spearman’s correlation coefficient between the logit of sensitivity and logit of 1-specificity was calculated to determine any threshold effect; A strong positive correlation would suggest threshold effect [29]. The between-study heterogeneity was evaluated using Q test and I2 statistics. A P value less than 0.10 for the Q test or I2 value ≥ 50% indicated substantial heterogeneity. A fixed effects model was used if no heterogeneity was observed. A random effects model was selected if significant heterogeneity was observed. Possible sources of heterogeneity were explored through a meta-regression analysis with covariates as follows: (1) country (China vs. countries other than China), (2) number of patients (˃ 45 vs. < 45), (3) location (ICU vs. OR), and (4) reference standard device(PiCCO vs. no-PiCCO).

Results

Characteristics of the studies

This meta-analysis yielded 279 primary studies after the initial independent review, comprising 278 published studies identified through electronic database searches and one published study identified through a manual search. Figure 1 shows the study selection process. A total of seven records were initially excluded due to duplicate records; 259 records were excluded due to the source not related to the research topic or being conference abstract; and seven records were excluded because PLR test was not performed. Finally, six studies[17, 18, 30,31,32,33] fulfilled all the inclusion criteria and were considered for analysis. They are all prospective single-center studies, the main characteristics of the eligible studies are shown in Table 1. The quality of the included studies was assessed using QUADAS-2 available in Fig. 2.

Fig. 1
figure 1

Flow diagram of identification of studies

Table 1 Characteristics of the studies included in this meta-analysis
Fig. 2
figure 2

Risk of bias and applicability concerns for the studies included in the meta-analysis. a Risk-of-bias graph and b risk-of-bias summary

Quantitative synthesis

Study data and individual diagnostic estimates are summarized in Table 2. Overall, 298 patients were included in this review, of whom 149 (50%) were fluid responsive. The cutoff values of ΔEtCO2 in four studies was 5%, one was 5.8% and the other one was an absolute increase 2 mmHg. The AUROC of individual studies ranged from 0.80 to 0.94. Heterogeneity between studies was assessed with an overall Q = 4.098, I2 = 51%, and P = 0.064, indicated substantial heterogeneity. Spearman’s correlation coefficient was − 0.6 (P = 0.28), indicating no threshold effect. The pooled sensitivity and specificity for the overall population were 0.79 (95% CI 0.72–0.85) and 0.90 (95% CI 0.77–0.96), respectively (Fig. 3). The pooled positive likelihood ratio and negative likelihood ratio were 8.2 (95% CI 3.2–20.5) and 0.23 (95% CI 0.16–0.32), respectively. The DOR was 35 (95% CI 12–107) (Fig. 4). The pooled AUROC was 0.81 (95% CI 0.77–0.84) (Fig. 5).

Table 2 Summary of results of the studies included in this meta-analysis
Fig. 3
figure 3

Forest plots of the pooled sensitivity and specificity. Each solid square represents an individual study. Error bars represent 95% CI. Diamond indicates the pooled sensitivity and specificity for all of the studies

Fig. 4
figure 4

Forest plots of the pooled diagnostic odds ratio. Each solid square represents an individual study. Error bars represent 95% CI. Diamond indicates the pooled diagnostic odds ratio for all of the studies

Fig. 5
figure 5

SROC curve of variation of end-tidal carbon dioxide for predicting fluid responsiveness. Each circle represents individual study estimates. The diamond is the summary point representing the average sensitivity and specificity estimates. The ellipses around this summary point are the 95% confidence region (dashed line) and the 95% prediction region (dotted line). The cutoff value of included studies: (1) Monge/2012 [16]: 5%; (2) Monnet/2013 [15]: 5%; (3) Zang/2013 [28]: 5%; (4) Wang/2015 [29]: 5%; (5) Toupin/2016 [30]: 2 mmHg; and (6) Yao/2016 [31]: 5.8%

Meta-regression analysis results

The results of the meta-regression analyses (Fig. 6) showed that the significant sources of heterogeneity in sensitivity and specificity were the number of patients larger than 45. Other factors, including country, location, and reference standard device, were not significantly different.

Fig. 6
figure 6

Graphs for meta-regression analysis. CI = confidence interval. Meta-regression was performed by country (China vs. countries other than China), number of patients (˃ 45 vs. < 45), location (ICU vs. OR), and reference standard device(PiCCO vs. no-PiCCO)

Publication bias and sensitivity analysis

The publication bias of the studies was assessed using the Deeks’ funnel plot asymmetry test. The slope coefficient of the six studies was associated with a P value of 0.01 (Fig. 7). The aforementioned results indicated significant publication bias. The sensitivity analysis (Fig. 8) showed that excluding Toupin’s study [32] negated the publication bias (P = 0.36). The sensitivity analysis also showed that the pooled DOR ranged from 21 to 140 and the pooled AUC ranged from 0.92 to 0.96 when one study was omitted.

Fig. 7
figure 7

Deeks’ funnel plot of publication bias among studies. ESS = effective sample size. Numbers 1 to 6 represent the study arms (Monge/2012, Monnet/2013, Zang/2013, Wang/2015, Toupin/2016, Yao/2016)

Fig. 8
figure 8

Graphs for sensitivity analysis

Discussion

The correct evaluation of intravascular volume and proper maintenance of cardiac preload can improve the prognosis of critically ill patients. Static variables could poorly predict fluid responsiveness [34,35,36,37]. However, dynamic indicators of fluid responsiveness, which are based on cardiopulmonary interactions in patients receiving mechanical ventilation, have been shown to be predictive [38,39,40,41,42]. The ΔEtCO2 has been extensively studied with respect to its value in predicting fluid responsiveness, but the results are conflicting [13,14,15,16,17,18, 30,31,32,33, 43,44,45]. To the best of our knowledge, this is the first systematic review and meta-analysis to explore the diagnostic accuracy of ΔEtCO2 in predicting fluid responsiveness during PLR test in patients with mechanical ventilation. The results confirmed that, overall, the ΔEtCO2 performed moderately in predicting fluid responsiveness in patients with mechanical ventilation during PLR test, with a pooled AUROC of 0.81 (95% CI 0.77–0.84), a pooled specificity and sensitivity of 0.90 (95% CI 0.77–0.96) and 0.79 (95% CI 0.72–0.85). These findings are clinically relevant because capnography was widely available for critically ill and surgical patients, and ΔEtCO2 values can be obtained immediately in the emergency or critical care setting and operation room.

The PLR test provides a dynamic assessment of preload dependence inducing a transient and reversible increase in cardiac preload. This test has been demonstrated to predict fluid responsiveness in many studies over a wide population, including clinical situations in which other parameters of fluid responsiveness have failed, such as patients with cardiac arrhythmias or with spontaneous breathing [8, 9]. However, the PLR must be interpreted in conjunction with changes in CO, velocity time integral, aortic blood flow velocity, carotid artery flow time [46], the measurement of such index often requiring expensive or invasive hemodynamic monitoring systems, resulting in its wide application is limited.EtCO2 can be easily determined with continuous waveform-capnography devices that are generally available in the clinical. In the present study, we showed that fluid responsiveness can be assessed using EtCO2 monitoring and PLR test. This provides a clinically useful way to predict fluid responsiveness using readily available diagnostic tools such as a PLR maneuver and EtCO2 measurement by capnography.

The present systematic review and meta-analysis had some limitations. First, this analysis included only six studies with a relatively small sample size even pooled analysis there are only 298 patients were included in this review; The 95% CI AUROC is between 0.77 and 0.84 and the studies heterogeneity is great. Therefore, the power and precision of the results were limited. Second, standard PLR maneuver was performed except for Toupin’s study [32], the time for assessing the change in CO and EtCO2 in Zang’s [30] studies was when PLR had induced its maximal effect on CI, other studies were recorded one minute after PLR, this could significantly impact the results. Third, the quality assessment showed a high risk of bias in the index test. This bias might have restricted the interpretation of the true diagnostic efficacy of ΔEtCO2 value in predicting fluid responsiveness. Forth, publication bias was observed among studies. We performed a sensitivity analysis and found that the pooled DOR ranged from 21 to 140 and the pooled AUC ranged from 0.92 to 0.96. This indicates that the results were stable despite the presence of publication bias. Finally, since more detailed individual patient data were not available, a more comprehensive analysis of diagnostic effect could not be conducted.

Conclusions

The study confirmed that the ΔEtCO2 performed moderately in predicting fluid responsiveness in patients with mechanical ventilation during PLR test. As the limited number of studies included and study heterogeneity, further studies with a larger dataset and well-designed models are required to confirm the diagnostic accuracy and utility of EtCO2 in predicting fluid responsiveness in patients with mechanical ventilation during PLR test.

Availability of data and materials

The datasets used and/or analyzed during the current study are available from the corresponding author on reasonable request.

Abbreviations

ΔEtCO2:

Variation of end-tidal carbon dioxide

PLR:

Passive leg raising

EtCO2:

End-tidal carbon dioxide

DOR:

Diagnostic odds ratio

CI:

Confidence interval

TP:

True positive

FP:

False positive

TN:

True negative

FN:

False negative

AUROC:

Area under the receiver operator characteristic curve

QUADAS-2:

Quality Assessment of Diagnostic Accuracy Studies

SROC:

Summary receiver operator characteristic

AUC:

Area under the SROC curve

References

  1. Byrne L, Van Haren F. Fluid resuscitation in human sepsis: time to rewrite history? Ann Intensive Care. 2017;7(1):4.

    Article  PubMed  PubMed Central  Google Scholar 

  2. Pinsky MR, Brophy P, Padilla J, Paganini E, Pannu N. Fluid and volume monitoring. Int J Artif Organs. 2008;31(2):111–26.

    Article  CAS  PubMed  Google Scholar 

  3. Wiedemann HP, Wheeler AP, Bernard GR, Thompson BT, Hayden D, deBoisblanc B, Connors AF Jr, Hite RD, Harabin AL. Comparison of two fluid-management strategies in acute lung injury. N Engl J Med. 2006;354(24):2564–75.

    Article  CAS  PubMed  Google Scholar 

  4. Acheampong A, Vincent JL. A positive fluid balance is an independent prognostic factor in patients with sepsis. Crit Care (London, England). 2015;19:251.

    Article  Google Scholar 

  5. Bindels AJ, van der Hoeven JG, Graafland AD, de Koning J, Meinders AE. Relationships between volume and pressure measurements and stroke volume in critically ill patients. Crit Care (London, England). 2000;4(3):193–9.

    Article  CAS  Google Scholar 

  6. Hu B, Xiang H, Liang H, Yu L, Xu T, Yang JH, Du ZH, Li JG. Assessment effect of central venous pressure in fluid resuscitation in the patients with shock: a multi-center retrospective research. Chin Med J. 2013;126(10):1844–9.

    PubMed  Google Scholar 

  7. Pinsky MR. Functional haemodynamic monitoring. Curr Opin Crit Care. 2014;20(3):288–93.

    Article  PubMed  PubMed Central  Google Scholar 

  8. Cavallaro F, Sandroni C, Marano C, La Torre G, Mannocci A, De Waure C, Bello G, Maviglia R, Antonelli M. Diagnostic accuracy of passive leg raising for prediction of fluid responsiveness in adults: systematic review and meta-analysis of clinical studies. Intensive Care Med. 2010;36(9):1475–83.

    Article  PubMed  Google Scholar 

  9. Cherpanath TG, Hirsch A, Geerts BF, Lagrand WK, Leeflang MM, Schultz MJ, Groeneveld AB. Predicting fluid responsiveness by passive leg raising: a systematic review and meta-analysis of 23 clinical trials. Crit Care Med. 2016;44(5):981–91.

    Article  PubMed  Google Scholar 

  10. Hartmann SM, Farris RW, Di Gennaro JL, Roberts JS. Systematic review and meta-analysis of end-tidal carbon dioxide values associated with return of spontaneous circulation during cardiopulmonary resuscitation. J Intensive Care Med. 2015;30(7):426–35.

    Article  PubMed  Google Scholar 

  11. Sandroni C, De Santis P, D’Arrigo S. Capnography during cardiac arrest. Resuscitation. 2018;132:73–7.

    Article  PubMed  Google Scholar 

  12. Touma O, Davies M. The prognostic value of end tidal carbon dioxide during cardiac arrest: a systematic review. Resuscitation. 2013;84(11):1470–9.

    Article  PubMed  Google Scholar 

  13. de Courson H, Chauvet J, Le Gall L, Georges D, Boyer P, Verchere E, Nouette-Gaulain K, Biais M. Utility of changes in end-tidal carbon dioxide after volume expansion to assess fluid responsiveness in the operating room: a prospective observational study. Br J Anaesth. 2020;125(5):672–9.

    Article  PubMed  Google Scholar 

  14. Lakhal K, Nay MA, Kamel T, Lortat-Jacob B, Ehrmann S, Rozec B, Boulain T. Change in end-tidal carbon dioxide outperforms other surrogates for change in cardiac output during fluid challenge. Br J Anaesth. 2017;118(3):355–62.

    Article  CAS  PubMed  Google Scholar 

  15. Jacquet-Lagrèze M, Baudin F, David JS, Fellahi J-L, Hu PB, Lilot M, Piriou V. End-tidal carbon dioxide variation after a 100- and a 500-ml fluid challenge to assess fluid responsiveness. Ann Intensive Care. 2016;6(1):37.

    Article  PubMed  PubMed Central  Google Scholar 

  16. Young A, Marik PE, Sibole S, Grooms D, Levitov A. Changes in end-tidal carbon dioxide and volumetric carbon dioxide as predictors of volume responsiveness in hemodynamically unstable patients. J Cardiothorac Vasc Anesth. 2013;27(4):681–4.

    Article  PubMed  Google Scholar 

  17. Monnet X, Bataille A, Magalhaes E, Barrois J, Le Corre M, Gosset C, Guerin L, Richard C, Teboul JL. End-tidal carbon dioxide is better than arterial pressure for predicting volume responsiveness by the passive leg raising test. Intensive Care Med. 2013;39(1):93–100.

    Article  CAS  PubMed  Google Scholar 

  18. Monge García MI, Gil Cano A, Gracia Romero M, Monterroso Pintado R, Pérez Madueño V, Díaz Monrové JC. Non-invasive assessment of fluid responsiveness by changes in partial end-tidal CO2 pressure during a passive leg-raising maneuver. Ann Intensive Care. 2012;2:9.

    Article  PubMed  PubMed Central  Google Scholar 

  19. Güney Pınar S, Pekdemir M, Özturan İ U, Doğan N, Yaka E, Yılmaz S, Karadaş A, Ferek Emir D. Assessment of end-tidal carbon dioxide and vena cava collapsibility in volume responsiveness in spontaneously breathing patients. Medizinische Klinik, Intensivmedizin und Notfallmedizin. 2020. https://doi.org/10.1007/s00063-020-00749-1

  20. Anderson CT, Breen PH. Carbon dioxide kinetics and capnography during critical care. Crit Care (London, England). 2000;4(4):207–15.

    Article  CAS  Google Scholar 

  21. Jin X, Weil MH, Tang W, Povoas H, Pernat A, Xie J, Bisera J. End-tidal carbon dioxide as a noninvasive indicator of cardiac index during circulatory shock. Crit Care Med. 2000;48(7):2415–9.

    Article  Google Scholar 

  22. Shibutani K, Muraoka M, Shirasaki S, Kubal K, Sanchala VT, Gupte P. Do changes in end-tidal PCO2 quantitatively reflect changes in cardiac output? Anesth Analg. 1994;79(5):829–33.

    Article  CAS  PubMed  Google Scholar 

  23. Moher D, Liberati A, Tetzlaff J, Altman DG. Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. Ann Intern Med. 2009;151(4):264–9.

    Article  PubMed  Google Scholar 

  24. Whiting PF, Rutjes AW, Westwood ME, Mallett S, Deeks JJ, Reitsma JB, Leeflang MM, Sterne JA, Bossuyt PM. QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies. Ann Intern Med. 2011;155(8):529–36.

    Article  PubMed  Google Scholar 

  25. Deeks JJ. Systematic reviews in health care: systematic reviews of evaluations of diagnostic and screening tests. BMJ (Clin Res Ed). 2001;323(7305):157–62.

    Article  CAS  Google Scholar 

  26. Glas AS, Lijmer JG, Prins MH, Bonsel GJ, Bossuyt PM. The diagnostic odds ratio: a single indicator of test performance. J Clin Epidemiol. 2003;56(11):1129–35.

    Article  PubMed  Google Scholar 

  27. Mandrekar JN. Receiver operating characteristic curve in diagnostic test assessment. J Thorac Oncol. 2010;5:1315–6.

    Article  PubMed  Google Scholar 

  28. Deeks JJ, Macaskill P, Irwig L. The performance of tests of publication bias and other sample size effects in systematic reviews of diagnostic test accuracy was assessed. J Clin Epidemiol. 2005;58(9):882–93.

    Article  PubMed  Google Scholar 

  29. Zamora J, Abraira V, Muriel A, Khan K, Coomarasamy A. Meta-DiSc: a software for meta-analysis of test accuracy data. BMC Med Res Methodol. 2006;6:31.

    Article  PubMed  PubMed Central  Google Scholar 

  30. Zang ZD, Yan J, Xu HY, Liang FM, Yang T, Wang DP, Gao F. The value of changes in end-tidal carbon dioxide pressure induced by passive leg raising test in predicting fluid responsiveness in mechanically ventilated patients with septic shock. Zhonghua Nei Ke Za Zhi. 2013;52(8):646–50.

    PubMed  Google Scholar 

  31. Xiao-ting W, Hua Z, Da-wei L, Hong-min Z, Huai-wu H, Yun L, Wen-zhao C. Changes in end-tidal CO2 could predict fluid responsiveness in the passive leg raising test but not in the mini-fluid challenge test: a prospective and observational study. J Crit Care. 2015;30(5):1061–6.

    Article  PubMed  Google Scholar 

  32. Toupin F, Clairoux A, Deschamps A, Lebon JS, Lamarche Y, Lambert J, Fortier A, Denault AY. Assessment of fluid responsiveness with end-tidal carbon dioxide using a simplified passive leg raising maneuver: a prospective observational study. Can J Anaesth. 2016;63(9):1033–41.

    Article  PubMed  Google Scholar 

  33. Yao T, Wu W, Zheng X, Fang Q. The value of end-tidal carbon dioxide partial pressure combined passive leg raising test on volume responsiveness assessment in shocked patients post cardiac operation. Zhonghua wei zhong bing ji jiu yi xue. 2016;28(5):391–5.

    PubMed  Google Scholar 

  34. Berkenstadt H, Margalit N, Hadani M, Friedman Z, Segal E, Villa Y, Perel A. Stroke volume variation as a predictor of fluid responsiveness in patients undergoing brain surgery. Anesth Analg. 2001;92(4):984–9.

    Article  CAS  PubMed  Google Scholar 

  35. Feissel M, Michard F, Mangin I, Ruyer O, Faller JP, Teboul JL. Respiratory changes in aortic blood velocity as an indicator of fluid responsiveness in ventilated patients with septic shock. Chest. 2001;119(3):867–73.

    Article  CAS  PubMed  Google Scholar 

  36. Keller G, Cassar E, Desebbe O, Lehot JJ, Cannesson M. Ability of pleth variability index to detect hemodynamic changes induced by passive leg raising in spontaneously breathing volunteers. Crit Care (London, England). 2008;12(2):R37.

    Article  Google Scholar 

  37. Michard F. Changes in arterial pressure during mechanical ventilation. Anesthesiology. 2005;103(2):419–28.

    Article  PubMed  Google Scholar 

  38. Cannesson M, Delannoy B, Morand A, Rosamel P, Attof Y, Bastien O, Lehot JJ. Does the Pleth variability index indicate the respiratory-induced variation in the plethysmogram and arterial pressure waveforms? Anesth Analg. 2008;106(4):1189–94.

    Article  PubMed  Google Scholar 

  39. Cannesson M, Desebbe O, Rosamel P, Delannoy B, Robin J, Bastien O, Lehot JJ. Pleth variability index to monitor the respiratory variations in the pulse oximeter plethysmographic waveform amplitude and predict fluid responsiveness in the operating theatre. Br J Anaesth. 2008;101(2):200–6.

    Article  CAS  PubMed  Google Scholar 

  40. Marik PE, Cavallazzi R, Vasu T, Hirani A. Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: a systematic review of the literature. Crit Care Med. 2009;37(9):2642–7.

    Article  PubMed  Google Scholar 

  41. Choi DY, Kwak HJ, Park HY, Kim YB, Choi CH, Lee JY. Respiratory variation in aortic blood flow velocity as a predictor of fluid responsiveness in children after repair of ventricular septal defect. Pediatr Cardiol. 2010;31(8):1166–70.

    Article  PubMed  Google Scholar 

  42. Monnet X, Dres M, Ferre A, Le Teuff G, Jozwiak M, Bleibtreu A, Le Deley MC, Chemla D, Richard C, Teboul JL. Prediction of fluid responsiveness by a continuous non-invasive assessment of arterial pressure in critically ill patients: comparison with four other dynamic indices. Br J Anaesth. 2012;109(3):330–8.

    Article  CAS  PubMed  Google Scholar 

  43. Baloch K, Rehman Memon A, Ikhlaq U, Umair M, Ansari MI, Abubaker J, Salahuddin N. Assessing the utility of end-tidal carbon dioxide as a marker for fluid responsiveness in cardiogenic shock. Cureus. 2021;13(2):13164.

    Google Scholar 

  44. Guinot PG, Godart J, de Broca B, Bernard E, Lorne E, Dupont H. End-expiratory occlusion manoeuvre does not accurately predict fluid responsiveness in the operating theatre. Br J Anaesth. 2014;112(6):1050–4.

    Article  CAS  PubMed  Google Scholar 

  45. Zhao H, Wang X, Liu D. The role of end-tidal carbon dioxide partial pressure in fluid responsiveness assessment in septic shock patient. Zhonghua Nei Ke Za Zhi. 2014;53(5):359–62.

    PubMed  Google Scholar 

  46. Laher AE, Watermeyer MJ, Buchanan SK, Dippenaar N, Simo NCT, Motara F, Moolla M. A review of hemodynamic monitoring techniques, methods and devices for the emergency physician. Am J Emerg Med. 2017;35(9):1335–47.

    Article  PubMed  Google Scholar 

Download references

Acknowledgements

None.

Funding

This work was supported by Zhejiang Traditional Chinese Medicine Science and Technology Project (No. 2020ZA046).

Author information

Authors and Affiliations

Authors

Contributions

HH and HX carried out the studies, participated in collecting data, and drafted the manuscript. CW and QS performed the statistical analysis and participated in its design. YF helped to draft the manuscript. All authors read and approved the final manuscript.

Corresponding author

Correspondence to Hua Xu.

Ethics declarations

Ethics approval and consent to participate

Not applicable.

Consent for publication

Not applicable.

Competing interests

All authors declare that they have no any conflict of interests.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Huang, H., Wu, C., Shen, Q. et al. Value of variation of end-tidal carbon dioxide for predicting fluid responsiveness during the passive leg raising test in patients with mechanical ventilation: a systematic review and meta-analysis. Crit Care 26, 20 (2022). https://doi.org/10.1186/s13054-022-03890-9

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s13054-022-03890-9

Keywords